DMX Personality

DMX Control

Loss of Signal Setting

Dimmer Control

OVATION™ FD-165WW User Manual Rev. 1
Set the DMX personality as follows.
1. Go to the SET main level.
2. Select the PERS programming level.
3. Select the desired personality: UNO (1-channel), DOS (2-channel),
or STD.P (3-channel).
·
See the
DMX Control
each personality.
·
Make sure that the starting addresses on the various products do not overlap
due to the new personality setting.
DMX Control allows you to assign each product to a unique starting address on the DMX
controller. All products with the same starting address will respond in unison.
1. Select a
DMX
Personality.
2. Set the running mode:
a. Go to the RUN main level.
b. Select DMX.
· Note: For information on the SLAV option, see
3. Set the starting address:
a. Go to the ADDR main level.
b. Select the starting address D.001–D.512.
The highest recommended starting address for each DMX mode is as follows:
DMX
DMX
Mode
Address
UNO
512
This setting controls how the product responds when the DMX signal is lost.
1. Go to the SET main level.
2. Select the DERR programming level.
3. Select BLAK to turn off the LEDs when the signal is lost.
4. Select SAVE to use the last command programmed when the signal is lost.
The OVATION™ FD-165WW may be plugged into and controlled using a regular dimmer
or by being plugged into constant power and using DMX control. By default the product
is set to SENS which automatically senses the type of power/control being used and sets
the product to react accordingly. The product may also be set to DMMR mode which
turns off the DMX control and only allows exclusive control of the product via the dimmer.
1. Go to the RUN main level.
2. Select the DMMR.
When SENS and DMMR modes are active, the only control panel button that will
work will be the <ENTER> button which will allow you to change modes.
section for the highest starting address you can select for
DMX
DMX
Mode
Address
DOS
Master/Slave
Mode.
DMX
Mode
511
STD.P
Operation
DMX
Address
508