Table Of Factory Default Parameter Settings - Xtender XTS 900-12 User Manual

Unit combining inverter, battery charger and transfer system
Table of Contents

Advertisement

20 TABLE OF FACTORY DEFAULT PARAMETER SETTINGS

Access
Param.
level
Basic
1107
Maximum current of AC source (Input limit)
Expert
1108
Battery undervoltage level without load
Expert
1109
Battery undervoltage level at full load
Expert
1110
Restart voltage after batteries undervoltage
Expert
1111
Autostart to the battery connection
Expert
1112
Inverter frequency
Expert
1121
Battery overvoltage level
Expert
1122
Restart voltage level after an battery overvoltage
Basic
1124
Inverter allowed
Expert
1125
Charger allowed
Basic
1126
Smart-Boost allowed
Expert
1127
Grid feeding allowed
Expert
1128
Transfer relay allowed
Expert
1130
After battery undervoltage
Expert
1131
After battery overvoltage
Expert
1132
After inverter or Smart-Boost overload
Expert
1134
After overtemperature
Basic
1138
Battery charge current
Expert
1139
Temperature compensation
Expert
1140
Floating voltage
Expert
1142
Force a new cycle
Expert
1143
Voltage level 1 to start a new cycle
Expert
1144
Time period under voltage level 1 to start a new cycle
Expert
1145
Voltage level 2 to start a new cycle
Expert
1146
Time period under voltage level 2 to start a new cycle
Expert
1147
Cycling restricted
Expert
1148
Minimal delay between cycles
Expert
1149
New cycle priority on absorption and equalization
phases
Expert
1155
Absorption phase allowed
Expert
1156
Absorption voltage
Expert
1157
Absorption duration
Expert
1158
End of absorption triggered with current
Expert
1159
Current limit to quit the absorption phase
Expert
1160
Maximal frequency of absorption control
Expert
1161
Minimal delay since last absorption
Expert
1162
Force equalization
Expert
1163
Equalization allowed
Expert
1164
Equalization voltage
Expert
1165
Equalization duration
Expert
1166
Number of cycles before an equalization
Expert
1168
End of equalization triggered with current
Expert
1169
Current threshold to end equalization phase
Expert
1170
Reduced floating allowed
Expert
1171
Floating duration before reduced floating
Expert
1172
Reduced floating voltage
Expert
1173
Periodic absorption allowed
Expert
1174
Periodic absorption voltage
Expert
1175
Reduced floating duration before periodic absorption
Expert
1176
Periodic absorption duration
Basic
1187
Standby level
The second value concerns the 120Vac ranges
2
User manual
Denomination / description
V4.6.0
Studer Innotec SA
Xtender
Fact. value
2
32 Aac
11.6/23.2/46.3 Vdc
10.5/21/42 Vdc
12/24/48 Vdc
No
50 Hz
17/34.1/68.2 Vdc
16.2/32.4/64.8 Vdc
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
60 Adc
-3 mV/°C/cell
13.6/27.2/54.4 Vdc
-
12.5/25/49.9 Vdc
30 min
12.3/24.6/49.2 Vdc
60 sec
No
3 hours
No
Yes
14.4/28.8/57.6 Vdc
2 hours
No
4 Adc
No
2 hours
-
No
15.6/31.2/62.4 Vdc
0.5 hours
25
No
4 Adc
No
1 days
13.2/26.4/52.8 Vdc
No
14.4/28.8/57.6 Vdc
7 days
0.5 hours
10%
Mod.
value
47