Elem.
Description
Automatic
V
earth-neutral
connection
Galvanic
W
isolator
Source
X
reversing
switch
Isolation
Y
transformer

18 MECHANICAL DIMENSION AND MOUNTING ELEMENTS

Pos.
Description
25
Mounting hook-up for XTS
26
Mounting hook-up for XTH
27
Access shutter to the top
fastening screw

19 NAMEPLATE (FIG. 1B)

Pos.
Denomination
30
Model
31
Pnom*/P30*
32
Pnom/P30
33
Udc Battery
Idc
34
Charge/inv/inv*
35
UAC-In
36
IAC-In
37
UAC-Out
I AC-Out
38
Inv/Inv*/max
39
SN:xxxxxxxxxx
40
IPxx
User manual
Comment
This connection is deactivated by default. In may be used in certain specific
cases for automatically re-establishing the neutral system type TT (TNC, TNS,
TNC-S) when the Xtender is in inverter mode. The activation is carried out via
RCC-02/-03 remote control by configuration of the parameter {1485}. This
operation may only be carried out by qualified personnel, under the
responsibility of these personnel, and in conformity with the local standards
and regulations. See 4.2.3 – p. 18.
This device (optional) is generally used to reduce the risk of electrolytic
corrosion due to the direct current when a boat is connected at the dock.
When the installation has more than one supply source, it is necessary to
install a switching device between the sources, simultaneously switching the
neutral and the phase(s) of these sources. In all cases this device (manual or
automatic) must guarantee interruption of the connected source before its
connection to another source.
This device (optional) prevents the risk of galvanic corrosion due to direct
currents when a boat is connected at the dock.
Comments
Delivered with the unit (without screws for wall mounting)
This flap should be resealed after tightening the screws to
prevent small animals that could damage the device from
entering.
Description
Model
Rated power output / power for 30 minutes
with external cooling fan ECF-01
Rated power output / power for 30 minutes
Rated battery voltage (accepted input
range)
Maximum current in charger/nominal
current in inverter/in inverter with external
cooling fan for XTS model
Maximum current at input / output
Rated AC input voltage (input range)
Rated output voltage in inverter mode
(possible adjustment range in inverter
mode)
Maximum charger current
Serial no.
Protection rating according to IEC 60529
V4.6.0
Comments
Model XTS only
See sect. 7.2 – p. 26.
See sect. 7.2.2 – p. 27.
When the transfer relay is
activated, the AC output
voltage is equivalent to AC
input voltage
See sect. 7.2.2 – p. 27.