(44) This indicator is lit continuously when the charger is working and has not yet reached its
absorption phase.
It flashes twice during the absorption phase and once during the floating phase. It will flash 3 times
whenever equalisation is activated.
If the Smart Boost mode has been activated, this indicator stops blinking temporarily when source
backup is required by users (loads).
(45) This indicator is lit continuously when an alternative voltage with correct values, either in
frequency {1112-1505-1506} or in voltage {1199}, is present at the AC input of the device and the
current limit set by the user has not been reached.
It flashes one time when the current limit at the input {1107} set by the user has been reached. In this
case the charger current is reduced in order to guarantee priority supply to the users (see sect. 7.2.2.2
- p. 27).
If the Smart Boost mode (see sect. 7.2.2.4 – p. 28) is used and the inverter is part of the user supply –
therefore the battery is discharged – the "charge" indicator (44) will be glowing.
If the input current is exceeded nevertheless, and this exceed not permitted by parameter{1436}, the
Xtender goes back to inverter mode (transfer relay open) and the indicator (42) will keep flashing as
long as the user current exceeds the limit value of the input current {1107}.
If grid feeding is allowed {1127} this indicator blinks 2 times while feeding.
(46) This indicator is lit continuously when an alternative voltage of 230V is present at the equipment
output. It flashes when the device is in "load search" mode according to sect. 7.1.1 – p. 26.
(47) Receipt button to stop the acoustic warning (XTM only). The duration of the acoustic alarm {1565}
by factory default is 0 sec (deactivated).

12 MAINTENANCE OF THE INSTALLATION

With the exception of periodic checks of connections (tightening and general condition), the
Xtender does not require any special maintenance.

13 PRODUCT RECYCLING

The models of the Xtender series conform to the European directive
2011/65/EU on hazardous substances and do not contain the following
elements: lead, cadmium, mercury, hexavalent chrome, PBB or PBDE.
To dispose of this product, please use the service for the collection of
electrical waste and observe all applicable obligations according to the
place of purchase.

14 EC DECLARATION OF CONFORMITY

The inverter and accessories described in this manual comply with the following directive and
standards:
Directive 2004/108/EC:
Reference standards: EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, EN 62040-2
Low voltage directive 2006/95/EC:
Reference standards: EN 50178/IEC 62103, EN 62040-1, EN 62109-1, EN 60950-1
Directive RoHS: 2011/65/EU