Order Of Steps During Commissioning; Operation; Taking Out Of Operation - ADS-tec VMT8000 series Instruction Manual

Terminals
Hide thumbs Also See for VMT8000 series:
Table of Contents

Advertisement

VMT8000 series
Recommendation for use:
The shielding of a data cable must always be connected with the connector
housing (EMC).

6.3 Order of steps during commissioning

Removing the lid from the service slot
Loosen the undetachable screws on the service slot cover by using a Torx Tx10 screw driver and
subsequently remove the service slot cover from the device.
Fig. 5:
Connecting the cables
Please connect all required cables. Always use the grommets to correctly install the cables.
ATTENTION
Breaching of IP protection
The device can be damaged if the service slot
cover is not attached or is attached incorrectly!
 Make sure that the service slot cover is
attached correctly before starting operation!
Recommendation for use:
Before attaching the service slot cover, make sure that the seal is clean,
undamaged and dry.

6.4 Operation

The device should be operated by trained and instructed personnel only.
The manufacturer must be contacted if damage is found.

6.5 Taking out of operation

The device can be shut down using the ON/OFF pushbutton, the ignition function and using the
software. The method to be used depends on the application case.
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen