Hardware Connections
9.1.2

LINE inputs

The Lyra can connect 7 analog line inputs. The Input numbers 1-4 and 7 (front side) are stereo inputs.
Input 5 and 6 are MONO inputs, with on the same connector a cleanfeed output, so these inputs can be
used for a telephone-hybrid.
You can hook up a telephone-hybrid to both MONO inputs. When one of the MONO inputs is routed to a
module and the module is routed to the PROG, SUB or both, the cleanfeed function will be activated
automatically. When activated all of the signals on the PROG, SUB or both will be added to the cleanfeed 1
(mono input 5) or 2 (mono input 6) buss except for the input signal.
Below you see a picture of the rear view. Here you see all 9Pin SUBD connectors which you can use
for the analog inputs.
Pin 1
Pin 6
Pin 2
Pin 7
Pin 3
Pin 8
Pin 4
Pin 9
Pin 5

Table 4: Pinning for Stereo Input 1..4 and Mono Input 5..6

The GPI line on the MONO connectors can be used to connect the RING from your telephone-hybrid.
Usually the 'Ring' signal comes from a REMOTE on your Hybrid. Consult your telephone-hybrid manual for
information about how to connect the RING to the GPI of the MONO input.
GPO-A and GPO-B make connection if the GPO is activated!
Maximum current:
Maximum resistance when connection made:
Maximum Voltage:
At the front side of the 19" rack you can find one additional stereo analog input. Below you can see a
picture of this section. You have the ability to adjust the input level with the potentiometer located at the left
side.
Lyra Digital Mixer from D&R Phone +31 294 418014, email:

Figure 8: Analog Line Inputs at rear side

Stereo Input 1..4
Left +
Left -
GND
Right +
Right -
GND
GPO A
GPO B
Not Connected

Figure 9: Analog Line Front Input

Mono Input 5..6
Mono IN +
Mono IN -
GND
Auto Cleanfeed OUT +
Auto Cleanfeed OUT -
GND
GPO A
GPO B
GPI
200 mA
12 Ohm
24 V