Installation Requirements
Because of potentially
inconsistent
voltage
capabilities,
the use of this dryer with power created
by gas powered
generators,
solar powered
generators,
wind powered
generators
or any other generator
other than the local utility
Electrical requirements for electric dryer
CIRCUIT - Individual
30 amp. branch
circuit fused with 30 amp. time delay fuses or circuit breakers.
Use separately
fused
circuits for washer and dryer. DO NOT operate
a washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire,
240 volt, single phase, 60 Hz, Alternating
Current.
This dryer is internally
grounded
to neutral
unless it was manufactured
for sale in Canada.
Only a 4-conductor
cord shall be used when the appliance
is installed
in a location
where grounding
through
the neutral
conductor
is prohibited.
Grounding
through
the neutral
link is prohibited
for: (1) new branch circuit installations,
(2)
mobile
homes, (3) recreational
vehicles, and (4) areas where local codes do not permit grounding
through the neutral.
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle
to be located
so the power supply cord is accessible
when the dryer is in the installed position.
GROUNDING
CONNECTION
- See "Grounding
requirements"
in Electrical
Installation
section.
3-WIRE
POWER SUPPLY CORD KIT (not supplied)
3-wire
receptacle
(NEMA
type 10-30R)
The dryer MUST employ a 3-conductor
power
supply cord NEMA 10-30 type SRDT rated at 240
volt AC minimum,
30 amp, with 3 open end spade
lug connectors
with upturned
ends or closed loop
connectors
and marked
for use with clothes dryers. For
3-wire
cord connection
instructions
see ELECTRICAL
CONNECTIONS
FOR A 3-WIRE
SYSTEM.
4-WIRE
POWER SUPPLY CORD KIT (not supplied)
4-wire
receptacle
(NEMA
type
14-30R)
The dryer MUST employ
a 4-conductor
power supply
cord NEMA 14-30 type SRDT or ST (as required)
rated
at 240 volt AC minimum,
30 amp, with 4 open end
spade Jug connectors
with upturned
ends or closed loop
connectors
and marked
for use with clothes dryers.
For
4-wire
cord connection
instructions
see ELECTRICAL
CONNECTIONS
FOR A 4-WIRE
SYSTEM.
NOTE
Dryers manufactured
for sale in Canada
have factory-
installed,
4-wire
power supply cord (NEMA
14-30R).