Advertisement

Available languages

Available languages

Quick Links

Installation
instructions
Gas &
Electric
Dryer
Pre-lnstallation
Requirements ................................
2
Electrical Requirements ........................................
2
Exhaust System Requirements ............................
3-4
Gas Supply Requirements .....................................
4
Location of Your Dryer..........................................
4-5
Mobile Home Installation .......................................
6
Rough-In Dimensions ..........................................
6-7
Unpacking ...........................................................
7
Reversing Door Swing ...........................................
7
Electrical Installation .............................................
8
Grounding Requirements .......................................
8
Electrical Connections--3-wire
..............................
9
Electrical Connections--4-wire
..............................
9
Gas Connection ...................................................
10
General Installation ..............................................
10
Replacement Parts..............................................
10
Before beginning
installation,
carefully
read these instructions.
This will simplify
the installation
and ensure
the dryer is installed correctly and safely. Leave these instructions
near the Dryer after installation
for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70.
NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1.
NOTE: The Dryer is designed under ANSI Z 21.5.1
or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME
USE only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
Save
These Instructions
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
1
P/N 134235400B (0404)

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 41794072301

  • Page 1 Pre-lnstallation Requirements ........ Electrical Requirements ........Exhaust System Requirements ......Gas Supply Requirements ........Location of Your Dryer.......... Mobile Home Installation ........Installation Rough-In Dimensions .......... instructions Unpacking ............Reversing Door Swing ........... Electrical Installation ..........Grounding Requirements ........Electrical Connections--3-wire ......
  • Page 2: What To Do If You Smell Gas

    POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. For your safety the information this manual must be followed to minimize the POWER SUPPLY CORD KIT- The dryer MUST employ a risk of fire or explosion or to prevent property 3-conductor power supply cord NEMA 10-30 type SRDT damage, personal injury or loss of life.
  • Page 3: Exhaust System Requirements

    EXHAUST SYSTEM REQUIREMENTS MAXIMUM LENGTH of 4" (10.2 cm) Dia. Rigid Metal Duct Use only 4 inch (10.2 cm) diameter (minimum) rigid or VENT HOOD TYPE flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in (Preferred) operation.
  • Page 4: Installation

    Although vertical orientation o f theexhaust system is 2. The gas supply line should be of 1/2 inch (1.27 cm) acceptable, certainextenuating c ircumstances couldaffect pipe. theperformance ofthedryer: 3. If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing •...
  • Page 5 MINIMUM INSTALLATION CLEARANCES - inches (cm) SIDES REAR FRONT Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm) 60 sq. inches Closet O(Ocm) O(Ocm) 15(38.1 cm) 1(2.54cm) (387.1 sq. cm) Closet door ventilation required: 2 Iouvered openings each 60 square inches (387 square centimeters) -- 3 inches (7.6 cm) from bottom and top of door.
  • Page 6 MOBILE HOME INSTALLATION UNDER COUNTER & STACK MODELS ROUGH-IN DIMENSIONS 1. Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred.
  • Page 7: Rear View

    CONSOLE MODELS UNPACKING ROUGH-IN DIMENSIONS 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove foam shipping base. To prevent damage, do not use the control panel (68.3 cm) as a means to pick up or move the dryer.
  • Page 8 ELECTRICAL INSTALLATION If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUSTbe plugged into an appropriate, copper ELECTRIC Dryer wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances. If in The following are spedfic requirements doubt, call a licensed electrician.
  • Page 9 GREEN GREEN POWER CORD GROU GROUND WIRE SILVER TERMINAL GROUND SCREW SILVER TERMINAL SCREW TERMINAL BLOCK NEUTRAL GROUND WIRE TIGHTEN GROUND TO THESE WIRE THREADS TIGHTEN TO THESE THREADS STRAIN RELIEF MOUNTING BRACKET POWER CORD ELECTRICAL CONNECTIONS BRACKET POWER CORD FOR 4- WIRE SYSTEM ELECTR/C Dryer...
  • Page 10: Gas Connection

    GAS CONNECTION 5. Run the dryer through a cycle check for proper 1. Remove the shipping cap from gas pipe at the rear of operation. the dryer. NOTE: On gas dryers, before the burner will light, it is NOTE: DO NOT connect the dryer to L.R gas service necessary for the gas line to be bled of air.
  • Page 11 Requerimientos de instalaciOn preliminares ..2 Requerimientos el_ctricos ....... Requerimientos del sistema de escape .... 3-4 Requerimientos del suministro de gas....Ubicaci6n de su secadora ....... InstalaciOn en casas mOviles ......Instrucciones Dimensiones para la instalaciOn ...... Desembalaje ..........para la Puerta reversible ..........
  • Page 12 ALIMENTACION ELECTRICA - Corriente alterna, monof_isica, 60 Para su seguridad, siga las Hz, 240 voltios; trifilar o tetrafilar. instrucciones contenidas en este manual a fin CORDON ELECTRICO - En la secadora se DEBE usar un cord6n de reducir a un minimo los riesgos de incendio o electrico trifilar NEMA 10-30 tipo SRDT para un voltaje nominal mfnimo de 240 voltios CA, 30 amp., con 3 conectores de...
  • Page 13 REQUERIMIENTOS DEL SISTEMA DE ESCAPE LARGO MAXIMO del Conducto Met&rico Rigido de 4" (10,2 cm) de Di&metro Utilice solamente ductos metalicos, r[gidos o flexibles de 4" (10,2 cm) de di_imetro (m[nimo)y una caperuza de salida de uso TIPO DE CAPERUZA DE SALIDA aprobado, con registros que giren hacia afuera que se abren (Preferido) cuando la secadora se encuentra en funcionamiento.
  • Page 14 Aungue u nsistema vertical sea aceptable, algunas 2. La tuber[a de alimentaci6n de gas debe ser de 1/2 pulgada circunstancias atenuantes pueden a fectar elfuncionamiento (1,27 cm) de di_imetro. lasecadora: 3. Si est,1 permitido pot los cOdigos locales, se puede usar Se debe utilizar solamente conductos metalicos rigidos.
  • Page 15 DESPEJES MiNIMOS DE INSTALACION - Pulgadas (cm) Parte Parte Parte Lados Trasera Superior De/antera Alcoba 0 (0 cm) 0 (0 cm) 15 (38,1 cm) Armario 0 (0 cm) 0 (0 cm) 15 (38,1 cm) 1 (2,54 cm) Ventilaci6n requirida en la puerta del armario: dos aberturas rejilladas cada 60 pulg? (387 cm2) -- 3"...
  • Page 16: Vista Lateral

    INSTALA CION EN CASAS MO VILES MODELOS DE DEBAJO DE MOSTRADOR 1. El tubo de escape de la secadora DEBE ser instalado hacia el Y APILADORES exterior (El escape debe colocarse en la parte exterior y no DIMENSIONES PARA LA INSTALACION debajo de la casa m6vil.) Debe usarse ducto de metal que no sea combustible.
  • Page 17 DESEMBALAJE MODEL OS A UTONOMOS CON CONSOLA SUPERIOR 1. Utilizando las cuatro esquineras de embarque de la caja de cart6n (dos a cada lado), coloque cuidadosamente la secadora sobre el DIMENSIONES PARA LA INSTALA CION costado izquierdo y saque la base de espuma de embarque. Para evitar da_os, no use el panel de control como un medio para levantar o mover la secadora.
  • Page 18 INSTALA CION ELL'CTRICA Si su secadora est,1 equipada con un cordon electrico que posee un conductor de puesta a tierra del equipo y un enchufe de puesta a tierra, dicho enchufe DEBE ser conectado a un Secadoras ELECTRICAS tomacorriente adecuado, debidamente instalado y puesto a tierra de acuerdo con todos los cOdigos y reglamentos locales.
  • Page 19 TORNILLO TORNILLO VERDE CONDUCTOR VERDE DE VERDE DE DE PUESTA CORDON ELCCTRICO BORNE PLATEADO PU ESTA A A TIERRA TABLERO DE BORNES TIERRA BORNE PLATEADO CABLE DE PUESTA A TIERRA NEUTRAL CABLE DE PUES_A A TIERRA NEGRO ATORNILLE BLANCO TUERCA EN ESTAS ROSCAS TUERCA SOPORTE...
  • Page 20: Piezas De Recambio

    CONEXION 1. Saque la tapa de embarque de la tuber[a de gas de la Haga funcionar la secadora durante un ciclo completo para secadora situada en la parte trasera. comprobar su buen funcionamiento. NOTA: En las secadoras a gas, antes de encender el quema- NOTA: NO conecte la secadora al suministro de propano, sin dor es necesario purgar el aire de la tuber[a del gas.