Installation
Requirements
Exhaust system requirements,
continued
A clothes dryer must be exhausted
outdoors.
Do not
exhaust dryer into a chimney, a wail, a ceiling, an attic,
a crawl space or any concealed
space of a building.
A
clothes dryer produces
combustible
lint.if the dryer is
notexhausted outdoors, some finelintwUl b eexpelled
into the laundry
area. An accumulation
of lint in any
area of the home can create a health and fire hazard.
ii
The dryer must be connected
to an exhaust outdoors.
Regularly
inspect the outdoor
exhaust opening
and remove
any accumulation
of lint around the outdoor
exhaust
opening
and in the surrounding
area.
FIRE HAZARD
*
Do not allow combustible
materials
(for example:
clothing,
draperies/curtains,
paper)
to come in
contact
with exhaust system. The dryer MUST NOT
be exhausted
into a chimney, a wall, a ceiling,
or any
concealed
space of a building
which
can accumulate
lint, resulting
in a fire hazard.
*
Do not screen the exhaust ends of the vent system, or
J
use any screws, rivets or other fasteners
that extend
J
into the duct to assemble the exhaust system. Lint can
become
caught
in the screen, on the screws or rivets,
clogging
the duct work and creating
a fire hazard
as well as increasing
drying times. Use an approved
vent hood to terminate
the duct outdoors,
and seal
J
all joints with metal foil duct tape. All male duct pipe
J
fittings
MUST be installed
downstream
with the flow
of air.
ii
WARNING .....................................................
FIRE HAZARD
Exceeding
the length of duct pipe or number of elbows
allowed
in the "MAXIMUM
LENGTH"
charts can cause
an accumulation
of lint in the exhaust system. Plugging
the system could create a fire hazard,
as well as
..... !ncrease drying
times. .......................................................................................
MAXIMUM
LENGTH
of 4" (102 ram)
Rigid
Metal
Duct
Z
o
VENT
HOOD
TYPE
(Preferred)
4 _
(10.2 crn)
Iouvered
0
64 ft. (19.5 m)
1
52 ft. (15.9 m)
2
44 ft. (13.5 m)
3
36 ft.
(11 m)
24 ft.
(7.3 m)
4
28 ft.
(9.5 m)
16 ft.
(4.9 m)
2.5"
(6.35cm)
48 ft. (14.6
m)
40 ft. (12.2 m)
32 ft. (9.8
m)
WARNING
FIRE HAZARD
*
Do not install flexible
plastic or flexible
foil venting
material.
If installing
semi-rigid
venting, do not exceed 8 ft.
7