Uniden UH8050S Owner's Manual

Uniden UH8050S Owner's Manual

Uhf cb transceiver
Hide thumbs Also See for UH8050S:
Table of Contents

Advertisement

UH8050S
UHF CB Transceiver
For more exciting new products please visit our website:
Australia: www.uniden.com.au
New Zealand: www.uniden.co.nz

Advertisement

Table of Contents
loading

Summary of Contents for Uniden UH8050S

  • Page 1 UH8050S UHF CB Transceiver For more exciting new products please visit our website: Australia: www.uniden.com.au New Zealand: www.uniden.co.nz...
  • Page 2: Table Of Contents

    Contents Introduction Controls & Connectors Indicators Included with your UH8050S Optional Accessories DIN Installation Connecting the Microphone Mounting the MIC Hanger Operation Turning on the Power Setting the Volume Setting the Manual Squelch Setting the Auto Squelch Selecting a Channel...
  • Page 3 Turning Instant Replay On/Off Close Call RF Capture Using Close Call Selective Calling Programming the Selcall ID for your UH8050S Storing Selcall IDs of other users to the ID Memory Tone Calling (Making a Selcall Call) Receiver Quiet (TSQ) Mode...
  • Page 4: Introduction

    Introduction The Uniden UH8050S is designed to provide you with years of trouble free service. Its rugged components and materials are capable of withstanding harsh environments. Please read this Operating Manual carefully to ensure you gain the optimum performance of the unit.
  • Page 5: Controls & Connectors

    Controls & Connectors UH8050S Base Front View Controls and Connectors 6 SCAN/MEM - Scan and Memory button 1 Rotary CHANNEL Selector 7 POLICE/DCS/CTCSS - Police/CB/Fire 2 SQ - Rotary Squelch control Button. DCS and CTCSS Tone button 3 MENU/ENTER - Menu and Select button...
  • Page 6 Controls & Connectors Heavy Duty Mic Controls and Connectors 15 CALL/SELCALL - Call Tone Button Selective Calling Button 16 INST - Instant Channel Button 17 PTT - Push To Talk Button 18 MICROPHONE 19 RJ45 type plug 20 Front MIC Jack Cover UNIDEN UH8050S UHF CB Transceiver...
  • Page 7 Tone Squelch Button - Move selection right 26 POWER - Power Button - Select Up and Down 27 MENU/ENTER - Menu and Buttons Select Buttton 38 RJ45 type plug - Move Selection Left 39 Front MIC Jack Cover 28 MICROPHONE 29 SPEAKER UNIDEN UH8050S UHF CB Transceiver...
  • Page 8: Indicators

    22 DCS/CTCSS Code Number/Extra RX 9 MON/SQT - Flashing: Monitor/ Channel Indicator Tight Squelch 23 TSQ - Tone Squelch enabled 10 INST - Instant Channel 11 DUAL/HOLD - Dual Watch/Hold 12 SCAN - Scan mode 13 Signal Power Level UNIDEN UH8050S UHF CB Transceiver...
  • Page 9: Included With Your Uh8050S

    Included with your UH8050S Transceiver Heavy Duty Mic (MK850) Owner’s Manual Microphone Hanger with screws, washers Din Mount Sleeve, Mounting Bracket DC Power Cord Mounting Screws Removable Bracket & with fuse Screws Washer Starts and Screws Adaptor Cable UNIDEN UH8050S UHF CB Transceiver...
  • Page 10: Optional Accessories

    Optional Accessories Remote LCD Speaker DECT Wireless Microphone Speaker Microphone (RM880) (MK800W) Extension Cable (EC 770) UHF Antenna - AT-870 External Speaker (MS100) UNIDEN UH8050S UHF CB Transceiver...
  • Page 11: Din Installation

    DIN Installation Mounting Using the DIN Bracket If you are unsure about how to install your UH8050S in your vehicle using the DIN bracket, consult your automobile manufacturer, dealer, or a qualified installer. The DIN bracket is made up of a sleeve and a frame. Before installing, confirm that your UH8050S fits in the desired mounting area and you have all the necessary materials to complete the task.
  • Page 12 2. Install the DIN sleeve into the DIN slot of your dashboard and secure it by bending the top and bottom folding tabs. 3. Slide UH8050S into the front frame. Ensure the threaded holes on UH8050S line up with holes on the front frame.
  • Page 13: Connecting The Microphone

    MIC jack until the connection locks into place. An optional 2m extension cable kit is available to enable mounting the main base in a hidden location. The unit will not function if connected to two Remote LCD Microphones (optional RM880) at the same time. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 14: Mounting The Mic Hanger

    (not supplied) High quality Double-Sided tape can be found at good retail stores. Secure the front and back pieces of the MIC Hanger using the supplied binding screws. Locate a suitable mounting position. Apply high quality Double-Sided tape onto the flat area of the MIC Hanger back piece and then press firmly to the mounting position. UNIDEN UH8050S UHF CB Transceiver...
  • Page 15 2. Drill a 13mm hole at the MIC hanger location. 3. Thread the microphone plug through the hole and connect with the extension cable. 4. Mount the MIC Hanger over the hole and cable. 5. At the Radio: Connect the extension cable plug to the MIC Jack. Fit the rubber bushing over the MIC jack. UNIDEN UH8050S UHF CB Transceiver...
  • Page 16: Operation

    Turning on the Power Press and hold VOL/PWR control at the base or the [POWER] button on the optional Remote SPK/MIC. Low-Voltage/High-Voltage Alert The UH8050S can operate on 12VDC (13.8V) or 24VDC (27.6V) power supply, with the range between 10.2VDC to 28.8VDC. If the power supply voltage exceeds 28.8VDC, an alert tone sounds and HI DC flashes for 5 seconds. The power source must not exceed 32VDC otherwise permanent damage may occur to your radio, which may not be covered by the manufacturer’s warranty.
  • Page 17: Setting The Manual Squelch

    SQL-1 - max sensitivity (min squelch) SQL-0 - Squelch open (monitor) SQL- OFF (SQ Volume on the BASE can be activated) 1. Press [SQL]. The squelch setting flashes. 2. Press on the optional Remote SPK/MIC to change the setting. UNIDEN UH8050S UHF CB Transceiver...
  • Page 18 Operation • If SQL-0 (squelch open) is selected then MON (monitor) icon flashes. • If SQL-4 (tight squelch) is selected then SQT icon flashes. • Selecting tight squelch mode may prevent the reception of weak signals. NOTE • High noise areas may still break the squelch. 3. Press [SQL] to store the setting. UNIDEN UH8050S UHF CB Transceiver...
  • Page 19: Selecting A Channel

    Turn the Rotary Channel Selector at the base or press on the optional Remote SPK/MIC to select the desired channel. Channel Banks - Using the POLICE Button The UH8050S has three banks (groups) of channels to select from; CB UHF CB + User programmable RX channels¹ Pre-programmed Police frequencies² FIRE Pre-programmed Fire & Ambulance frequencies²...
  • Page 20: Programming The Instant Priority Channel

    Momentarily press [INST] to return to the Instant Channel. Press [INST] again to return to the previous channel. Transmitting The UH8050S transmits only on UHF-CB Channels. For your reference a list of the available channels, corresponding frequencies and guidelines for their use and selection is printed on p.51 - p.52. For Australia, Channels 05 and 35 are reserved for Emergency NOTE Calls.
  • Page 21: Ctcss (Continuous Tone Coded Squelch System)

    Remote SPK/MIC to select DCS/CTCSS code. Press [DCS/CTCSS] once to store the new setting. To turn off CTCSS (or DCS) select the oFF code during setting. DCS (Digital Coded Squelch) DCS is a digital extension of CTCSS. It provides 104 extra, digitally coded, squelch codes that follow after the 38 CTCSS codes. CTCSS 1-38, followed by DCS 1-104. UNIDEN UH8050S UHF CB Transceiver Follow the steps for setting a CTCSS code.
  • Page 22: Call Tone Function (Wake Up Tones)

    Instant channel and the current channel for activity (see Programming the Instant Priority Channel, p.20). Press and hold [DUAL]. DUAL icon appears and two beeps will sound. To cancel DUAL Watch press and hold [DUAL]. DUAL icon disappears. • Every 1.5 seconds the Instant channel is monitored for 100msec. • Dual watch function stops temporarily when receiving a signal. NOTE • Dual watch function is invalid in Scan mode. UNIDEN UH8050S UHF CB Transceiver...
  • Page 23: Using Repeater Channels

    CH02 on Duplex Mode will Receive on CH02 but Transmit on CH32 etc... If you transmit on CH01 Duplex mode, you are actually transmitting on CH31 the repeater station down-converts your signal and retransmits on CH01. UNIDEN UH8050S UHF CB Transceiver...
  • Page 24: Operating The Uhf Cb Radio In Duplex Mode

    Group Scan (GS) and Master Scan (M.SCN) (a special case of Group Scan). During SCAN the UH8050S only checks channels or frequencies that are in the SCAN Memory, which are indicated by the M (memory) icon. The UH8050S maintains two SCAN Memories; one for Open Scan (OS) mode and the other for Group Scan (GS mode, to give you flexibility and allow you to use the radio more effectively.
  • Page 25: Add/Remove Channels From Scan Memory

    RX only Channels (CH22, CH23, CH61, CH62 and CH63), User Programmable RX Channels (CH81 to CH180) and Police or Fire (& Ambulance) channels group will not be included in MASTER SCAN Mode even though stored into GS Memory Also channels for which NOTE Duplex Setting are On will be skipped in MASTER SCAN Mode. UNIDEN UH8050S UHF CB Transceiver...
  • Page 26 4. Turn the Rotary Channel Selector to select the desired Subcode (CTCSS or DCS). 5. Press and hold the [MENU] to save and exit from the Menu Mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 27: Open Scan (Os) Mode

    3 seconds for the signal to return, otherwise scanning resumes. After transmission in scan mode, the unit will wait 20 seconds for the signal to return, otherwise scanning resumes. To deactivate SCAN, press [SCAN]. If SCAN is deactivated while on an active channel, the UH8050S will stay on that active channel. If no channels are active, the UH8050S will reinstate the starting channel. NOTE OS Mode is indicated by the absence of the GS icon. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 28: Group Scan (Gs) Mode

    2. Turn the Rotary Channel Selector to change the setting between ON and OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 29: Priority Watch

    ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If SCAN is deactivated while it is tuned to an active channel, the UH8050S will stay on that active channel. If none of the channels are active, the UH8050S will reinstate the scan start channel. NOTE If OS/GS Scanning is initiated when there are no channels programmed in OS/GS memory, an error tone will be heard and scanning will not start (see Add/Remove Channels from SCAN Memory, p.25).
  • Page 30: Busy Channel Lockout

    2. Turn the Rotary Channel Selector to change the setting between ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UH8050S will automatically exit the Menu Mode. NOTE Roger Beep 1.
  • Page 31: Key Beep On/Off

    ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 32: Volume Sync

    3. Press and hold [MENU] to save & exit from the menu mode. • When volume sync function is active, the volume of base and optional Remote SPK/MIC are synchronized. • Volume sync function can be used only when the optional Remote NOTE SPK/MIC is connected If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 33: Backlight Colour

    2. Turn the Rotary Channel Selector to change the setting between ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 34: Operation - Special Features

    Operation - Special Features 100 User Programmable RX Channels The UH8050S has 100 receive only channels (CH81 to CH180) which can be programmed with frequencies ranging from 400-520MHz (in 12.5kHz steps). The extra RX channels only appear, as part of the CB channel bank, when a frequency has been programmed to a channel. There are three ways to programme RX channels;...
  • Page 35: Store A Frequency Found Using Close Call To A Rx Channel

    2. Change the RX channel by rotating the channel knob. 3. Press and hold [ENTER]. A confirmation tone sounds to indicate the new channel is programmed. The RX channel number flashes. 4. If a name is desired press [SCAN] to begin Alpha Tag edit (see manual programming above). 5. Press and hold [ENTER], or wait for 10sec, to exit programming mode. UNIDEN UH8050S UHF CB Transceiver...
  • Page 36: Instant Replay

    On. Press and hold [REPLAY] to turn Instant Replay On/Off. Two beep tones sound. Turn Instant Replay Off if you want to prevent the current 1 minute of recordings from being overwritten. UNIDEN UH8050S UHF CB Transceiver...
  • Page 37: Close Call Rf Capture

    Operation - Special Features Close Call RF Capture ™ The Close Call RF Capture feature sets the UH8050S so it detects and then displays the frequency of a nearby strong radio transmission. Close Call RF capture works great for finding frequencies at venues such as malls and sporting events. Close Call RF Capture doesn’t tune to a frequency to check for a transmission, instead it directly detects the presence of a strong, nearby signal and instantly tunes to the source’s frequency. The UH8050S only tries to find Close Call transmissions from 400-...
  • Page 38: Using Close Call

    3. Press and hold [HOLD] to unlock the currently displayed frequency. Two beeps sound. 4. Press [MENU] to resume Close Call RF Capture mode. • Close Call RF Capture feature is separate to and cannot be operated at the same time as SCAN or normal receive mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 39: Selective Calling

    Therefore Selcall is a group feature used by groups with similarly set up radios. The UH8050S has a Selective Calling system. Exceptional features, like 10 Selcall ID Memories, Receiver Quieting, Tone Squelch Scanning, Tone and Group Calling make the UH8050S superior to other transceivers in its class. Receiver Quieting (Tone Squelch) When activated on individual UHF-CB channels (except for emergency CH05 and CH35), it automatically mutes the receiver audio circuit of the radio. It will stay in this Quiet mode as long as the Selcall tone code (Selcall ID) required to open the muting circuit is not received.
  • Page 40: Programming The Selcall Id For Your Uh8050S

    Selcall settings menu as follows: 1. Power Off the UH8050S. 2. Press and hold [POWER] and [MENU]. The UH8050S should turn on in the SELCALL Menu selection state (no tone will sound). Cd dispays to indicate the Call ID setting (factory default ID is 00000).
  • Page 41: Tone Calling (Making A Selcall Call)

    CAL will display when transmitting the Selcall. An acknowledge tone coming from the called radio will be received if you have successfully made contact. The acknowledge tone for the UH8050S is a succession of three low tone beeps. Receiver Quiet (TSQ) Mode Puts the receiver in the QUIET mode (also known as the Tone Squelch (TSQ) mode) for the selected channel. When activated, the transceiver prevents any unwanted...
  • Page 42: To Activate/Deavtivate Tone Squelch (Tsq) On A Channel

    Refer to p.40, ‘Alarm Mode’ for other alarm settings) and displays the CAL icon. c) Flashes the TSQ icon for about 20 seconds allowing you to use the PTT button. If you are not able to respond within the 20 second period, TSQ icon stops flashing and ‘QUIET’ mode resumes. The UH8050S can decode a Selcall call even though not in ‘QUIET’ mode. NOTE UNIDEN UH8050S UHF CB Transceiver...
  • Page 43: Scanning Tone Squelched Channels

    Scanning can be increased in many different ways. You can either decrease the number of channels to be scanned thus increasing the scanning speed – or – change some of the Selcall parameters (refer to NOTE ‘Selcall Programming’). UNIDEN UH8050S UHF CB Transceiver...
  • Page 44: Group Calling

    Operation - Special Features Group Calling The UH8050S has the capability to respond to Group Calling and to transmit Group Calling Codes. Group Calling allows you to call members of your group simultaneously. However, to do this, you need to follow a certain format (see below) when programming your TX Selcall Selcall ID Format To call Transmitter SELCALL ID 10 radios [X] [X] [X] [X] [A] 100 radios...
  • Page 45: Selcall Settings

    Period setting. Otherwise you will not be able to selectively call one another. NOTE The UH8050S allows you to select which Tone Period is best for you. The three most commonly used tone settings (40,70 or 100 mSec) are available. With the freedom to change this parameter, you can easily adapt to the existing system in your group without the inconvenience of having the unit serviced by the dealer.
  • Page 46: Lead-In Delay Programming

    Operation - Special Features Lead-in Delay Programming 1. Power Off the UH8050S. 2. Press and hold [POWER] and [MENU]. The SELCALL Settings Menu will display (no tone will sound). 3. Press [MENU] repeatedly to select the Lead-in Delay setting - which is indicated on the display as Ld.
  • Page 47: Alarm Mode

    Operation - Special Features Alarm Mode When a received code matches to your receiver Selcall ID the UH8050S will respond based on the Call Alarm mode. Call Alarm - Auto mode (Default) a) Transmit an Acknowledge tone to the Caller.
  • Page 48: Selcall Tone Frequency List

    71.9 141.3 74.4 146.2 77.0 151.4 79.7 156.7 82.5 162.2 85.4 167.9 88.5 173.8 91.5 179.9 94.8 186.2 97.4 192.8 100.0 203.5 103.5 210.7 107.2 218.1 110.9 225.7 114.8 233.6 118.8 241.8 123.0 250.3 127.3 UNIDEN UH8050S UHF CB Transceiver...
  • Page 49: Dcs Codes Table

    DCS Codes Table DCS Code DCS Code DCS Code Code No. Code No. Code No. (Octal) (Octal) (Octal) UNIDEN UH8050S UHF CB Transceiver...
  • Page 50: Uhf Cb Channel Guidelines

    The above situations are not a fault of the radio but a symptom of mixed wideband and narrowband radios in current use. It is expected that as older wideband radios are phased out this issue will be eliminated. UNIDEN UH8050S UHF CB Transceiver...
  • Page 51: Uhf Cb Channels & Frequencies

    477.300 (CH36) 477.050 476.575 477.325 (CH37) 477.075 476.600 477.350 (CH38) 477.100 476.625 477.125 476.650 477.150 476.675 477.175 476.700 477.200 476.725 477.225 476.750 477.250 476.775 477.275 476.800 477.300 476.825 477.325 476.850 477.350 476.875 477.375 476.900 477.400 UNIDEN UH8050S UHF CB Transceiver...
  • Page 52 477.0625 476.5875 477.3375 (CH 77) 477.0875 476.6125 477.3625 (CH 78) 477.1125 476.6375 477.1375 476.6625 477.1625 476.6875 477.1875 476.7125 477.2125 476.7375 477.2375 476.7625 477.2625 476.7875 477.2875 476.8125 477.3125 476.8375 477.3375 476.8625 477.3625 476.8875 477.3875 476.9125 477.4125 UNIDEN UH8050S UHF CB Transceiver...
  • Page 53: Warranty

    IMPORTANT: Satisfactory evidence of the original purchase is required for warranty service Please refer to our Uniden website for any details or warranty durations offered in addition to those contained below. Warrantor: The warrantor is either Uniden Australia Pty Limited ABN 58 001 865 498 (“Uniden Aust”) or Uniden New Zealand Limited (“Uniden NZ”) as the case may be.
  • Page 54 Product was first purchased, if you believe that your Product does not conform with this warranty, you should deliver the Product, together with satisfactory evidence of your original purchase (such as a legible copy of the sales docket) to Uniden at the addresses shown below. You should contact Uniden regarding any compensation that may be payable for your expenses incurred in making a warranty claim. Prior to...
  • Page 55 UNIDEN UH8050S UHF CB Transceiver...
  • Page 56 © 2014 Uniden Australia Pty Limited. Uniden New Zealand Ltd. Printed in Vietnam. U01UT960ZZZ(0)

Table of Contents