Summary of Contents for Uniden UH8080NB

  • Page 1 UH8080NB Remote Speaker MIC UHF CB Transceiver For more exciting new products please visit our website: Australia: www.uniden.com.au New Zealand: www.uniden.co.nz...
  • Page 2: Table Of Contents

    Contents Introduction Controls & Connectors Indicators Included with your UH8080NB Transceiver Connecting the Microphone Mounting the MIC Hanger Operation Turning on the Power Setting the Auto Squelch Selecting a Channel Channel Banks - Using the POLICE button Programming the Instant Priority Channel...
  • Page 3 Contents Selective Calling Programming the Selcall ID for your UH8080NB Storing Selcall IDs of other users to the ID Memory Tone Calling (Making a Selcall Call) Receiver Quiet (TSQ) Mode To Activate/Deavtivate Tone Squelch (TSQ) on a Channel Receiving a Selcall...
  • Page 4: Introduction

    Introduction The Uniden UH8080NB is designed to provide you with years of trouble free service. Its rugged components and materials are capable of withstanding harsh environments. Please read this Operating Manual carefully to ensure you gain the optimum performance of the unit.
  • Page 5: Controls & Connectors

    Controls & Connectors Base (Front & Rear) EXT.SP. ANT. DC 13.8V DC 27.6V Remote LCD Speaker MIC UNIDEN UH8080NB UHF CB Transceiver...
  • Page 6 SQL - Squelch Button POWER - Power Button REPLAY - Replay Button MENU - Menu Button - Move selection right /ENTER - Enter Button - Move selection left - Select Up and Down Buttons MICROPHONE RJ45 type plug SPEAKER Front MIC Jack Cover UNIDEN UH8080NB UHF CB Transceiver...
  • Page 7: Indicators

    DCS/CTCSS - DCS/CTCSS selected MON/SQT - Flashing: Monitor/ Tight Squelch DCS/CTCSS Code Number /Extra RX Channel Indicator INST - Instant Channel TSQ - Tone Squelch enabled DUAL/HOLD - Dual Watch/Hold SCAN - Scan mode Signal Power Level UNIDEN UH8080NB UHF CB Transceiver...
  • Page 8: Included With Your Uh8080Nb Transceiver

    DC Power Cord (EC770) with mounting screws with fuse Optional Accessories: • UHF Antenna • External Speaker Visit the UH8080NB page on the website for more information on the availability of optional accessories: www.uniden.com.au for Australia Mounting Bracket, www.uniden.co.nz for New Zealand Mounting Screws,...
  • Page 9: Connecting The Microphone

    Disconnecting the MIC from the MIC Jack Pull back the rubber cover and move it down along the cord. Using the flat blade of a screwdriver or similar object carefully push the lock tab of the MIC plug towards the MIC cord and at the same time tug on the MIC cord to draw back the MIC plug. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 10: Mounting The Mic Hanger

    (not supplied) High quality Double-Sided tape can be found at good retail stores. Secure the front and back pieces of the MIC Hanger using the supplied binding screws. Locate a suitable mounting position. Apply high quality Double-Sided tape onto the flat area of the MIC Hanger back piece and then press firmly to the mounting position. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 11 2. Drill a 13mm hole at the MIC hanger location. 3. Thread the microphone plug through the hole and connect with the extension cable. 4. Mount the MIC Hanger over the hole and cable. 5. At the Radio: Connect the extension cable plug to the MIC Jack. Fit the rubber bushing over the MIC jack. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 12: Operation

    Operation Turning on the Power Press and hold [POWER]. Low-Voltage/High-Voltage Alert The UH8080NB can operate on 12VDC (13.8V) or 24VDC (27.6V) power supply, with the range between 10.2VDC to 28.8VDC. If the power supply voltage exceeds 28.8VDC, an alert tone sounds and HI DC flashes for 5 seconds. The power source must not exceed 32VDC otherwise permanent damage may occur to your radio, which may not be covered by the manufacturer’s warranty. NOTE If the input voltage falls below 10.2VDC, LO DC flashes for 5 seconds. The power turns off automatically if voltage falls below 9.0VDC.
  • Page 13: Setting The Auto Squelch

    SQL-2 - moderate sensitivity SQL-3 - medium sensitivity SQL-4 - minimum sensitivity (max/tight squelch) 1. Press [SQL]. The squelch setting flashes. 2. Press to change the setting. • If SQL-0 (squelch open) is selected then MON (monitor) icon flashes. • If SQL-4 (tight squelch) is selected then SQT icon flashes. • Selecting tight squelch mode may prevent the reception of weak signals. NOTE • High noise areas may still break the squelch. 3. Press [SQL] to store the setting. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 14: Selecting A Channel

    Operation Selecting a Channel Press to select the desired channel. Channel Banks - Using the POLICE Button The UH8080NB has three banks (groups) of channels to select from; CB UHF CB + User programmable RX channels¹ Pre-programmed Police frequencies² FIRE Pre-programmed Fire & Ambulance frequencies² When the CB icon is showing the 80 UHF-CB and any user programmed RX channels will be available for selection or scanning.
  • Page 15: Programming The Instant Priority Channel

    Momentarily press [INST] to return to the Instant Channel. Press [INST] again to return to the previous channel. Transmitting The UH8080NB transmits only on UHF-CB Channels. For your reference a list of the available channels, corresponding frequencies and guidelines for their use and selection is printed on p.43 - p.45. For Australia, Channels 05 and 35 are reserved for Emergency NOTE Calls.
  • Page 16: Ctcss (Continuous Tone Coded Squelch System)

    DCS (Digital Coded Squelch) DCS is a digital extension of CTCSS. It provides 104 extra, digitally coded, squelch codes that follow after the 38 CTCSS codes. CTCSS 1-38, followed by DCS 1-104. Follow the steps for setting a CTCSS code. Press until the DCS codes appear. Press [DCS/CTCSS] to set. The DCS icon and code will display. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 17: Call Tone Function (Wake Up Tones)

    In normal Simplex operation, your radio transmits on one particular frequency and receives on that same frequency. If there is a barrier that partially blocks your transmitted signal, the probability of another radio receiving the signal is very slim. Hills, tall buildings, metallic structures,...etc tend to act as a screen between radios. Standard Operation without the aid of a Repeater station. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 18: Operating The Uhf Cb Radio In Duplex Mode

    ON or OFF (standard channel numbering). 3. Press and hold [MENU] to save & exit from the menu mode. DUP icon displays when a selected channel is set to Duplex mode. • Only channels 01 - 08, and channels 41 - 48 are available for Duplex. • Check with your local Retailer for information on available repeaters. • If a button is not pressed within 10 seconds the UHF CB Radio will NOTE automatically exit the Menu Mode. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 19: Scanning

    SCAN only checks channels or frequencies that are in the SCAN Memory, which are indicated by the M (memory) icon. The UH8080NB has two SCAN Memory modes; Open Scan (OS) mode and Group Scan (GS) mode, to give you flexibility and allow you to use the radio more effectively. Furthermore, any combination of the three channel groups can be scanned by pressing [POLICE] during scan to select the desired channel groups.
  • Page 20: Open Scan (Os) Mode

    Allows continuous scanning of all selected channels. If an active channel is found, scanning will stop on that channel. If the received signal ceases, the unit will wait 3 seconds for the signal to return, otherwise scanning resumes. After transmission in scan mode, the unit will wait 20 seconds for the signal to return, otherwise scanning resumes. To skip the active channel, press momentarily. To deactivate SCAN, press [SCAN]. If SCAN is deactivated while on an active channel, the UH8080NB will stay on that active channel. If no channels are active, the UH8080NB will reinstate the starting channel. NOTE OS Mode is indicated by the absence of the GS icon. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 21: Group Scan (Gs) Mode

    2. Press to change the setting between ON and OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 22: Priority Watch

    ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If SCAN is deactivated while it is tuned to an active channel, the UH8080NB will stay on that active channel. If none of the channels are active, the UH8080NB will reinstate the scan start channel. NOTE If OS/GS Scanning is initiated when there are no channels programmed in OS/GS memory, an error tone will be heard and scanning will not start (see Add/Remove Channels from SCAN Memory, p.19).
  • Page 23: Busy Channel Lockout

    ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UH8080NB will automatically exit the Menu Mode. NOTE Roger Beep 1. Press [MENU] six times.
  • Page 24: Key Beep On/Off

    ON or OFF. 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 25: Volume Sync

    3. Press and hold [MENU] to save & exit from the menu mode. • The speaker that is not selected for control maintains its previous volume setting. • When an optional External Speaker is connected to the Ext.Sp. jack of the base, it substitutes for the Base unit speaker which becomes muted. NOTE Therefore 01 MAIN & 03 SYNC control the External Speaker in place of the base unit speaker. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 26: Backlight Colour

    01 (low contrast) to 10 (high contrast). 3. Press and hold [MENU] to save & exit from the menu mode. If a button is not pressed within 10 seconds the UHF CB Radio will automatically exit the Menu Mode. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 27: Operation - Special Features

    Operation - Special Features 100 User Programmable RX Channels The UH8080NB has 100 receive only channels (CH81 to CH180) which can be programmed with frequencies ranging from 400-520MHz (in 12.5kHz steps). The extra RX channels only appear, as part of the CB channel bank, when a frequency has been programmed to a channel. There are three ways to programme RX channels;...
  • Page 28: Store A Police/Fire Frequency To A Rx Channel

    2. Change the RX channel using if desired. 3. Press and hold [ENTER]. A confirmation tone sounds to indicate the new channel is programmed. The RX channel number flashes. 4. If a name is desired press [SQL] to begin Alpha Tag edit (see manual programming above). 5. Press and hold [ENTER], or wait for 10sec, to exit programming mode. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 29: Instant Replay

    On. Press and hold [REPLAY] to turn Instant Replay On/Off. Two beep tones sound. Turn Instant Replay Off if you want to prevent the current 1 minute of recordings from being overwritten. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 30: Close Call Rf Capture

    Operation - Special Features Close Call RF Capture ™ The Close Call RF Capture feature sets the UH8080NB so it detects and then displays the frequency of a nearby strong radio transmission. Close Call RF capture works great for finding frequencies at venues such as malls and sporting events. Close Call RF Capture doesn’t tune to a frequency to check for a transmission, instead it directly detects the presence of a strong, nearby signal and instantly tunes to the source’s frequency. The UH8080NB only tries to find Close Call transmissions from...
  • Page 31: Using Close Call

    3. Press and hold [HOLD] to unlock the currently displayed frequency. Two beeps sound. 4. Press [MENU] to resume Close Call RF Capture mode. • Close Call RF Capture feature is separate to and cannot be operated at the same time as SCAN or normal receive mode. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 32: Selective Calling

    Therefore Selcall is a group feature used by groups with similarly set up radios. The UH8080NB has a Selective Calling system. Exceptional features, like 10 Selcall ID Memories, Receiver Quieting, Tone Squelch Scanning, Tone and Group Calling make the UH8080NB superior to other transceivers in its class. Receiver Quieting (Tone Squelch) When activated on individual UHF-CB channels (except for emergency CH05 and CH35), it automatically mutes the receiver audio circuit of the radio. It will stay in this Quiet mode as long as the Selcall tone code (Selcall ID) required to open the muting circuit is not received.
  • Page 33: Programming The Selcall Id For Your Uh8080Nb

    Selcall settings menu as follows: 1. Power Off the UH8080NB. 2. Press and hold [POWER] and [MENU]. The UH8080NB should turn on in the SELCALL Menu selection state (no tone will sound). Cd dispays to indicate the Call ID setting (factory default ID is 00000).
  • Page 34: Tone Calling (Making A Selcall Call)

    CAL will display when transmitting the Selcall. An acknowledge tone coming from the called radio will be received if you have successfully made contact. The acknowledge tone for the UH8080NB is a succession of three low tone beeps. Receiver Quiet (TSQ) Mode Puts the receiver in the QUIET mode (also known as the Tone Squelch (TSQ) mode) for the selected channel. When activated, the transceiver prevents any unwanted...
  • Page 35: To Activate/Deavtivate Tone Squelch (Tsq) On A Channel

    Refer to p.40, ‘Alarm Mode’ for other alarm settings) and displays the CAL icon. c) Flashes the TSQ icon for about 20 seconds allowing you to use the PTT button. If you are not able to respond within the 20 second period, TSQ icon stops flashing and ‘QUIET’ mode resumes. The UH8080NB can decode a Selcall call even though not in ‘QUIET’ mode. NOTE UNIDEN UH8080NB UHF CB Transceiver...
  • Page 36: Scanning Tone Squelched Channels

    Scanning can be increased in many different ways. You can either decrease the number of channels to be scanned thus increasing the scanning speed – or – change some of the Selcall parameters (refer to NOTE ‘Selcall Programming’). UNIDEN UH8080NB UHF CB Transceiver...
  • Page 37: Group Calling

    Operation - Special Features Group Calling The UH8080NB has the capability to respond to Group Calling and to transmit Group Calling Codes. Group Calling allows you to call members of your group simultaneously. However, to do this, you need to follow a certain format (see below) when programming your TX Selcall Selcall ID Format To call Transmitter SELCALL ID 10 radios [X] [X] [X] [X] [A] 100 radios...
  • Page 38: Selcall Settings

    Period setting. Otherwise you will not be able to selectively call one another. NOTE The UH8080NB allows you to select which Tone Period is best for you. The three most commonly used tone settings (40,70 or 100 mSec) are available. With the freedom to change this parameter, you can easily adapt to the existing system in your group without the inconvenience of having the unit serviced by the dealer.
  • Page 39: Lead-In Delay Programming

    Operation - Special Features Lead-in Delay Programming 1. Power Off the UH8080NB. 2. Press and hold [POWER] and [MENU]. The SELCALL Settings Menu will display (no tone will sound). 3. Press [MENU] repeatedly to select the Lead-in Delay setting - which is indicated on the display as Ld.
  • Page 40: Alarm Mode

    Operation - Special Features Alarm Mode When a received code matches to your receiver Selcall ID the UH8080NB will respond based on the Call Alarm mode. Call Alarm - Auto mode (Default) a) Transmit an Acknowledge tone to the Caller.
  • Page 41: Selcall Tone Frequency List

    71.9 141.3 74.4 146.2 77.0 151.4 79.7 156.7 82.5 162.2 85.4 167.9 88.5 173.8 91.5 179.9 94.8 186.2 97.4 192.8 100.0 203.5 103.5 210.7 107.2 218.1 110.9 225.7 114.8 233.6 118.8 241.8 123.0 250.3 127.3 UNIDEN UH8080NB UHF CB Transceiver...
  • Page 42: Dcs Codes Table

    DCS Codes Table DCS Code DCS Code DCS Code Code No. Code No. Code No. (Octal) (Octal) (Octal) UNIDEN UH8080NB UHF CB Transceiver...
  • Page 43: Uhf Cb Channel Guidelines

    The above situations are not a fault of the radio but a symptom of mixed wideband and narrowband radios in current use. It is expected that as older wideband radios are phased out this issue will be eliminated. UNIDEN UH8080NB UHF CB Transceiver...
  • Page 44: Uhf Cb Channels & Frequencies

    477.300 (CH36) 477.050 476.575 477.325 (CH37) 477.075 476.600 477.350 (CH38) 477.100 476.625 477.125 476.650 477.150 476.675 477.175 476.700 477.200 476.725 477.225 476.750 477.250 476.775 477.275 476.800 477.300 476.825 477.325 476.850 477.350 476.875 477.375 476.900 477.400 UNIDEN UH8080NB UHF CB Transceiver...
  • Page 45 477.0625 476.5875 477.3375 (CH 77) 477.0875 476.6125 477.3625 (CH 78) 477.1125 476.6375 477.1375 476.6625 477.1625 476.6875 477.1875 476.7125 477.2125 476.7375 477.2375 476.7625 477.2625 476.7875 477.2875 476.8125 477.3125 476.8375 477.3375 476.8625 477.3625 476.8875 477.3875 476.9125 477.4125 UNIDEN UH8080NB UHF CB Transceiver...
  • Page 46: Warranty

    IMPORTANT: Satisfactory evidence of the original purchase is required for warranty service Please refer to our Uniden website for any details or warranty durations offered in addition to those contained below. Warrantor: The warrantor is either Uniden Australia Pty Limited ABN 58 001 865 498 (“Uniden Aust”) or Uniden New Zealand Limited (“Uniden NZ”) as the case may be.
  • Page 47 Product was first purchased, if you believe that your Product does not conform with this warranty, you should deliver the Product, together with satisfactory evidence of your original purchase (such as a legible copy of the sales docket) to Uniden at the addresses shown below. You should contact Uniden regarding any compensation that may be payable for your expenses incurred in making a warranty claim. Prior to...
  • Page 48 © 2013 Uniden Australia Pty Limited. Uniden New Zealand Ltd. Printed in Vietnam. U01UT957ZZZ(0)