Page 2
KIEN1005A Industrial Ethernet Switch Hardware Installation Manual Disclaimer: Kyland Technology Co., Ltd. tries to keep the content of this manual as accurate and as updated as possible. This document is not guaranteed to be error-free, and we reserve the right to amend it without notice to users.
Page 3
Notice for Safety Operation The product performs reliably as long as it is used accord- ing to the guidance. Artificial damage or destruction of the device should be avoided. Before using the device, read this notice carefully for personal and equipment safety. Please keep the manual for further reference.
Page 4
● Do not operate the device or connect or disconnect cables during an electrical storm. ● Use compatible connectors and cables. If you are not sure, contact our sales or technical support personnel for confirmation. ● Do not disassemble the device by yourself. When an anomaly occurs, contact our sales or technical support personnel.
PIS, power SCADA, wastewater treatment, metallurgy, intelligent transportation, rail transit, and many other industries. KIEN1005A supports both DIN rail and panel mounting. Table 1 lists the models supported by KIEN1005A. Table 1 KIEN1005A Models...
Structure and Interface 2 Structure and Interface Caution: To keep ports clean and ensure switch performance, you are advised to purchase the port dustproof shield (optional). 2.1 Front Panel KIEN1005A-1S/M-4T Front Panel (1)(2)(3) Figure 1 KIEN1005A-1S/M-4T Front Panel...
Page 8
Structure and Interface Table 2 Description of KIEN1005A-1S/M-4T Front Panel No. Identifier Description PWR1 Power 1 LED PWR2 Power 2 LED 100Base-FX Ethernet port LED 100Base-FX Ethernet port 10/100Base-T(X) Ethernet port 10/100Base-T(X) Ethernet port speed LED (yellow) 10/100Base-T(X) Ethernet port...
Page 9
Structure and Interface KIEN1005A -5T Front Panel Based on the voltage input range, KIEN1005A adopts either of the following front panels: When the voltage input is 24DCW or 12DCW, the appearance of KIEN1005A-5T front panel is shown in Figure 2.
Page 10
Structure and Interface Table 3 KIEN1005A-5T Front Panel (1) Identifier Description PWR1 Power 1 LED PWR2 Power 2 LED 10/100Base-T(X) Ethernet port 10/100Base-T(X) Ethernet port speed LED (yellow) 10/100Base-T(X) Ethernet port connection status LED (green)
Page 11
Structure and Interface When the voltage input is 220AC/DCW, the appearance of KIEN1005A- 5T front panel is shown in Figure 3. Figure 3 KIEN1005A-5T Front Panel (2) Table 4 KIEN1005A-5T Front Panel (2) No. Identifier Description Power LED 10/100Base-T(X) Ethernet port...
Page 12
Structure and Interface KIEN1005A –E-5T Front Panel Figure 4 KIEN1005A-E-5T Front Panel Table 5 KIEN1005A-E-5T Front Panel No. Identifier Description Power LED 10/100Base-T(X) Ethernet port 10/100Base-T(X) Ethernet port speed LED (yellow) 10/100Base-T(X) Ethernet port connection status LED (green)
Structure and Interface 2.2 Top Panel The series switches support both single and redundant power supplies with the following top panels respectively, as shown in Figure 5 and Figure 6. Top Panel (1) — Redundant power supply PWR1 PWR2 +/L -/N -/N +/L Figure 5 Top Panel (1) Table 6 Top Panel (1)
Page 14
Structure and Interface Top Panel (2) — Single power supply +/L -/N Figure 6 Top Panel (2) Table 7 Top Panel (2)
Mounting 3 Mounting 3.1 Dimension Drawing 91.5 Figure 7 Dimensions for DIN-Rail Mounting (Unit: mm) 91.5 25.8 Figure 8 Dimensions for Panel Mounting (Unit: mm) Caution: As part of the heat dissipation system, the switch housing becomes hot during operation. Please use caution when coming in contact and avoid covering the switch housing when the switch is running.
Step 1: Select the mounting position for KIEN1005A and guarantee adequate space for it. Step 2: Insert the upper connecting seat of KIEN1005A into the top of the DIN rail, and push the bottom of the device inward and upward to ensure the DIN rail fits in the connecting seat, as shown in the left of Figure 9.
Page 17
Step 1: Open the spring locking piece of the connecting seat with a screw driver, as shown in the left of Figure 10. Step 2: Move KIEN1005A in the direction of arrow 2 and the bottom of KIEN1005A outward in the direction of arrow 3. In this way, you can remove KIEN1005A from DIN rail.
Move KIEN1005A in direction 1 until the four screws are in the Ф4 positions. Then tighten the screws. In this way, KIEN1005A is firmly mounted to the wall or inner wall of a cabinet. Ф4 Ф6.5...
Page 19
Mounting Panel Dismounting Step 1: Loosen the four screws with a screwdriver. Move the device upward until the four screws are in the Ф6.5 positions in the following figure. Then remove the plate for panel mounting from the four screws to detach the device from the wall or inner wall of the cabinet.
Cable Connection 4 Cable Connection 4.1 10/100Base-T(X) Ethernet Port 10/100Base-T(X) Ethernet port is equipped with RJ45 connector. The port is self-adaptive. It can automatically configure itself to work in 10M or 100M state, full or half duplex mode. The port can also adapt to MDI or MDI-X connection automatically.
Page 21
Cable Connection Wiring Sequence RJ45 connector RJ45 connector Straight-through cable Wiring sequence Cross-over cable Wiring sequence Figure 14 Connection Using Straight-through/Cross-over Cable Note: he color of the cable for RJ45 connector meets the 568B standard: 1-orange and white, 2-orange, 3-green and white, 4-blue, 5-blue and white, 6-green, 7-brown and white, and 8-brown.
Cable Connection 4.2 100Base-FX Ethernet Port 100Base-FX Ethernet port is equipped with FC/ST/SC connector, and each port consists of TX (transmit) port and RX (receive) port. To enable data transmission between Switch A and Switch B, connect the TX (transmit) port of Switch A to the RX (receive) port of Switch B, and the RX (receive) port of Switch A to the TX (transmit) port of Switch B.
Cable Connection 4.3 Grounding Grounding protects the device from lightning and interference. Therefore, you must ground the device properly. There is a grounding screw on the top panel of the switch. The screw is for chassis grounding. After crimping one end of the grounding cable to a cold pressed terminal, secure the end to the grounding screw and connect the other end to the earth firmly (cross-sectional area of the grounding cable>25mm...
Cable Connection 4.4 Power Terminal Block There is a power terminal block on the top panel of the switch. You need to connect the power cable to the terminal block to provide power for the switch. The switch supports both single and redundant power supplies. For details, see Table 1.
Page 25
Wiring and Mounting Step 1: Ground the device properly according to section 4.3. Step 2: Remove the power terminal block from KIEN1005A. Step 3: Insert one end of the power cable into the power terminal block according to Table 9 to fix the power cable.
Page 26
Cable Connection PGND PWR2:-/N PWR1:-/N PWR2:+/L PWR1:+/L Plug Socket Figure 18 Cable Connection of 5-Pin 5.08mm-Spacing Plug-in Terminal Block 3-Pin 5.08mm-Spacing Plug-in Terminal Block (single power supply) Figure 19 shows the pin numbers of the 3-pin 5.08mm-spacing plug- in terminal block. +/L -/N Figure 19 3-Pin 5.08mm-Spacing Plug-in Terminal Block (socket)
Page 27
Wiring and Mounting Step 1: Ground the device properly according to section 4.3. Step 2: Remove the power terminal block from KIEN1005A. Step 3: Insert one end of the power cable into the power terminal block according to Table 10 to fix the power cable.
Page 28
Cable Connection PGND PWR -/N PWR +/L Figure 20 Cable Connection of 3-Pin 5.08mm-Spacing Plug-in Terminal Block Caution: The device supports 24DC, 24DCW, 12DCW, and 220AC/DCW power input. Before connecting the device to power supply, make sure that the power input meets the power requirement. If connected to an incorrect power input, the device may be damaged.
Basic Features and Specifications 6 Basic Features and Specifications...
Page 32
FAX: +86-10-88796678 Website: http://www.kyland.com Email: support@kyland.com For more information about KYLAND products, please visit our website: http://www.kyland.com...
Need help?
Do you have a question about the KIEN1005A and is the answer not in the manual?
Questions and answers