Page 3
EMC protection for power supply input terminal, excellent EMC protection performance for the Ethernet RJ45 port, RS232 and RS485 port enable the KIEN2032 to adapt the tough and dangerous industrial environment. The redundant function of the optical...
Page 4
This document is used together with the Kyvision Industrial Ethernet Switch Dedicated Network Management User’s Manual. Statement: For continuous update and perfection of the product and technology, the contents of this material may not be consistent with the actual product, please contact with us about related contents. If it is necessary for you to query the latest information on the product, please query our cooperation Website or contact with your local ser vice representative directly.
Page 5
Safety Notices This product can provide excellent and reliable performance within its design scope. However, it needs to avoid the damage or destroy by human reasons. Read this Manual thoroughly and keep it well for future reference. Do not place the equipment next to the source of water and the damp place. ...
Page 6
Description of Warning Mark: This manual uses two kinds of obvious warning marks to prompt users that more attention should be paid during operation. The meanings of these marks as follows: Warning: The comment after this mark should be paid more attention, the incorrect operation will cause the switch to be damaged seriously or it will cause body injury for the operator.
Contents Chapter1 System Overview.......................... 1 Product Overview .......................... 1 Features ............................2 Packing List and Unpacking Check ....................3 Chapter2 Performance Index........................5 2.1 System Index ............................5 2.2Service interface ........................... 6 Service Functions........................... 7 Chapter3 Hardware Structure........................9 System structure..........................9 Switch Structure...........................
Page 8
5.1.3 WEB Network Management....................41 Application of Data Ports ......................44 5.2.1 As TCP Server ........................44 5.2.2 As TCP Client ........................45 5.2.3 UDP Method ..........................45 Chapter 6 Testing Methods........................47 Self Testing ...........................47 Testing of Ethernet Ports ......................47 6.3 Testing of Fiber Ports .........................48 Data Ports Test..........................49 Chapter 7 Networking Modes and System Configuration..............51 Networking Modes ........................51...
EMC protection for power supply input terminal, excellent EMC protection performance for the Ethernet RJ45 port, RS232 and RS485 port enable the KIEN2032 to adapt the tough and dangerous industrial environment. The redundant function of the optical...
The packing box contains following contents: KIEN2032 3-pin DC Power Supply Terminal 8-pin Data Interface Terminal KIEN2032 Industrial Ethernet Switch User’s Manual Kyvision Industrial Ethernet Switch Dedicated Network Management User’s accompanying with 1 software CD Customer Service Manual Ф3 Grounding Cool Terminal, M3*8 Grounding Screw...
Page 12
Avoid the KIEN2032 drops after the box is opened. If the hard material is used to open this box, the hard material should not enter the case body too much to prevent the internal equipment damaged.
Chapter2 Performance Index 2.1 System Index The system performance index of the KIEN2032 industrial Ethernet switch is shown as table 2-1. Table2-1 System Index System Index KIEN2032 3 10Base-T/100Base-TX Quantity of RJ45 port Quantity of uplink redundant 2 100Base-FX-SM/MM fiber port...
Chapter2 Performance Index 2.3 Service Functions Connection of Serial Data In KIEN2032, a serial port server is embedded to make serial data into Ethernet packets and realize Ethernet switching and transmitting for serial data. Independent Management of Serial Port Server...
Page 16
KIEN2032 is able to set the working mode of all ports through management: full/half duplex, auto-sensing, enforced full/half duplex, enforced 10M/100M etc. Setting for Port Rate KIEN2032 is able to set the rate of all ports through management as any integer multiple of 32kbps.
Chapter3 Hardware Structu re 3.1 System structure The hardware architecture of the KIEN2032 industrial Ethernet switch is shown as Figure .3-1. Switching Network Controller Power Power Port protections Serial Data Server CONSO 口 Ethernet Ports DATA1 DATA2 Port 4 Port 8 1.
It spurns the traditional fan for heating removal, and reduces the power consumption of the whole equipment as well as improves the stability of the system. The profile of the case for the KIEN2032 is shown as Figure .3-2.
3.2.2 Front Panel The front panel of the KIEN2032 industrial Ethernet switch integrates with 2 pairs of optical fiber interfaces, 3 10Base-T/100Base-TX Ethernet RJ45 ports, 1 power supply input terminal, 1 data interface terminal and 9 system and port operation indication lights as shown as Figure .3-3.
Page 20
Figure .3-3 Front Panel Diagram Optical Fiber Interface The KIEN2032 presents 2 pairs of 100Base-FX full duplex single mode or multi-mode optical fiber interface with uplink redundancy; the port number is 4 and 8. The connector can select the SC or FC. The optical fiber interface should...
Page 21
Power Input Terminal The KIEN2032 uses the DC24V power supply. It uses the 3.81 ㎜ gap 3-wire phoenix terminal to connect to the power supply. The diameter of the power supply is less than 1.5 ㎜.
Page 22
Figure .3-4 Connection Diagram of DC Power Supply Terminal Data Interface The KIEN2032 presents 2 serial data, the factory default port number for the first data is 10001, whose interface method may be RS232 or RS485 (Configured according to the requirement of users). The factory default port number for the second data is 10002, whose interface method is coexist for RS232 and RS485.
Extinguish The port has not set up any effective network connection. 3.2.3 Top Panel The front panel of the KIEN2032 industrial Ethernet switch integrates with the network management interface and the property setting switching as shown as Figure .3-6. -15-...
Page 24
Figure .3-6 Top Panel Structure Network Management Interface (CONSOLE) The network management interface of the KIEN2032 is the shielded RJ45 socket with shield, the interface communication standard is the 3-wire RS232. Users can use the network management wire whose one terminal is RJ45 and the other terminal is DB9F to connect the network management interface of the KIEN2032 with the 9-pin serial port of the control computer.
Page 25
Figure .3-7 Connection Diagram of KIEN2032 Network Management Wire Property Setting Switch There is two bit of property setting switch for the KIEN2032, which are defined as T and F respectively. T is used to set the redundancy mode and common direct connection mode for 2 pair of optical interfaces.
3.2.4 Bottom Panel The bottom panel of the KIEN2032 presents a grounding screw hole, accompanying with M3 * 8 grounding screw and Ф3 grounding cool pressure terminal. As is shown in Figure .3-8, after one terminal of the grounding wire is presses to the cool press terminal, the grounding screw is used to fix the grounding hole of the crust.
4.2 Installation of Main Machine 4.2.1 Rail Installation For most of the industrial application, it is convenient to install the 35 ㎜ standard DIN rail. When you take out of the packaging box, the rear panel of the KIEN2032 should -21-...
Page 30
DIN rail connection socket. The dimension of the rail installation is shown as Figure .4-1. If the KIEN2032 needs to be installed to the DIN rail, should check the installation condition of the DIN rail before it is installed. To check the following:: 1....
For some application occasion, it is not convenient to install the DIN rail, so it is more applicable to use the wall-mounted installation. KYLAND can provide users with the wall-mounted plate which is the assembly used to the wall-mounted installation for the KIEN2032. The dimension of the wall-mounted installation is shown as Figure .4-3. -23-...
Page 32
KIEN2032 Industrial Ethernet Switch User's Manual Figure .4-3 Dimension Diagram of KIEN2032 Wall-mounted Installation Note: The wall-mounted plate is not the standard configuration of the KIEN2032. If it is necessary for our company to provide this configure, please order it individually when you purchase.
Page 33
Chapter4 Hardware Installation DIN rail connection socket. 2. Take out the wall-mounted plate and the wall-mounted plate screw from the packaging (“+” rail screw M3 * 6). Use the “+” screw driver to install the wall-mounted plate to the position where the DIN rail connection socket was installed.
Page 34
4 M3 screw at the back. Finally, the screw should not be screwed tightly and retain about 5mm distance. 4. After fixing the screw to the wall, install the KIEN2032 to selected position to enable 4 screws to pass through 4 Ф6.5 holes of the wall-mounted plate. Slip down the KIEN2032.
Chapter4 Hardware Installation 4.3 Cable Connection After the KIEN2032 is installed correctly, the installation connection of cable can be implemented. The cable connection of following interface is mainly contained. 1. Service Interface The terminal equipment interface provided by KIEN2032 is...
Page 36
KIEN2032 Industrial Ethernet Switch User's Manual Warning: This switch uses the laser to transmit the signal on the fiber cable. The laser complies with the level 1 requirement of the laser product, the general operation does not harm to your eyes. However, when it powers on, do not watch the optical transmission port and the end face of the optical fiber terminator by naked eye.
Chapter4 Hardware Installation 3. Connect one terminal of the optical cable to the optical fiber interface of the switches, another terminal is connected to the optical fiber interface of another equipment. It is shown as Figure .4-6. 4. After the connection completes, check the optical interface LNK/ACT indication light which corresponds to the front panel of the switch.
Page 38
KIEN2032 Industrial Ethernet Switch User's Manual 9. When the tail cable is laid out, the optical cable knot should be prevented and turning should be reduced as much as possible. Furthermore, the turning radius should not be too small. The knot should be tightened moderately and should not be too tightened.
Data Port 5.1 Configuration of Data Port In KIEN2032, a serial data server is built in, which transfers the two serial data into TCP/IP protocol and connects to the Ethernet. The TCP/IP protocol can support both the connection-based TCP protocol and the connectionless UDP protocol. Hence, any computer on the network can control the serial port equipment and share the information of the serial port equipment.
Page 40
Use serial port wire to connect the serial port of one control computer to the serial port1 of the KIEN2032, open the super terminal program of the output which is set to 9600, 8, none, 1 and without traffic control. Continuously enter 3 lowercase x characters to the super terminal window when it is powered on the KIEN2032, until the super terminal window displays the setting menu.
1. Server Setting It will set the parameter of the KIEN2032 serial data server when 0 is selected, such as IP address, subnet mask and gateway. Note that the IP address should be unique in the LAN. The subnet mask setting is defined by adopting the bits of the actual binary mask 0, such as the 255.255.255.0 is set to 8.
Page 42
KIEN2032 Industrial Ethernet Switch User's Manual Table5-1 Corresponding Table of Subnet Mask Subnet Mask KIEN2032 Serial Data Server Setting 255.255.255.252 255.255.255.248 255.255.255.240 255.255.255.224 255.255.255.192 255.255.255.128 255.255.255.0 255.255.254.0 255.255.252.0 255.255.248.0 255.128.0.0 255.0.0.0 This item should also contain the Telnet password setting and provide the telnet port 9999 with password protection.
Page 43
Chapter5 Configuration And Application of Data Port Table5-2 Binary Corresponding Table of Interface Mode Option Bit7 RS-232C RS-422/485 RS-485 2-wire word length word length Without check Odd check Even check 1 stop bit 2 stop bit Where, the type of common value is shown as follows: Table5-3 Corresponding Table of Common Interface Mode Type Binary...
Page 44
KIEN2032 Industrial Ethernet Switch User's Manual Table 5-4 Value Corresponding Table of Traffic Control Type Hexadecimal No Flow Control (by default) XON/XOFF Software Control RTS/CTS Hardware Control XON/XOFF Control, but the control character is also transmitted to the host. Port Number: The local port number of this serial port. For the TCP protocol, it is the port number intercepted locally.
Page 45
When the KIEN2032 is set to the modem simulation mode and the serial port is in the idle status, the KIEN2032 can still be taken as the server to -37-...
Page 46
Remote Port Number: Attempt to set up the remote port number for the connection. When the KIEN2032 is used as the telnet UNIX system host for the terminal, the port number should be set to 23.
Page 47
Chapter5 Configuration And Application of Data Port will be closed. (Only when both the Telnet method and the EOT method are set at the same time, this function acts.) Clear Buffer Mode: It is the two hexadecimal which is used to set the clear method of the buffering area data for the serial port and network interface when the connection is set up or terminated.
Page 48
KIEN2032 Industrial Ethernet Switch User's Manual Table5-8 Binary Value Corresponding Table of Data Packet Control Type Type Wait 12ms to send Waiting the Wait 52ms to send serial port Wait 250ms idle time send Wait 5ms to send None Send...
If the WEB method is expected to use, modify the IP address of the computer which is used to set to be within the same network segment with the KIEN2032. Use ping command in the computer after the KIEN2032 is connected to the network correctly such as ping 192.168.0.123 After the response is confirmed correctly, launch the IE browser and enter 192.168.0.123 into the address column, the interface as is shown in Figure .5-7 is...
Page 50
Basic Parameter Setting Figure .5-9 Basic Parameter Query This page indicates the basic information of KIEN2032 such as IP address, subnet mask, gateway address, MAC address and the parameters of two serial ports. The parameters can not be set at this page.
Page 51
Chapter5 Configuration And Application of Data Port Figure .5-10 Basic Parameter Setting This page sets the IP address, subnet mask, gateway IP address and TELNET logon password of KIEN2032. 3. Ports Parameters Setting Figure .5-11 Serial Ports Parameter Setting This page can set various parameters of serial port 1 and serial port 2. For the meanings of various items, refer to the introduction of the console network management.
5.2.2 As TCP Client In the optical fiber network of KIEN2032, if one terminal is set to the TCP server way, another terminal is set to the TCP Client way. The TCP Client powers on to connect the server automatically, and implement the point to point connection between two serial data ports.
Page 54
KIEN2032 Industrial Ethernet Switch User's Manual Equipment A Equipment B Equipment C IP Address: 192.168.0.123 IP Address: 192.168.0.124 IP Address: 192.168.0.125 Subnet Mask: 8 Subnet Mask: 8 Subnet Mask: 8 Gateway: None Gateway: None Gateway: None Serial Port 1: Serial Port 1:...
6.2 Testing of Ethernet Ports As showed in the Figure 6-1, the KIEN2032 is powered on to connect any two Ethernet ports with two testing computers with direct link network wires. Send PING command each other.
KIEN2032 Industrial Ethernet Switch User's Manual 6.3 Testing of Fiber Ports Use two KIEN2032 switches to build an optical fiber link network as is shown in the Figure .6-2. Connect any one fiber port of a switch with a testing computer with direct link network wires.
The RS232 interface for the first channel of data for KIEN2032 is connected to the COM1 port of the test computer2 or the RS485 interface of the first channel of data is connected to the COM2 port of the test computer2 by the RS232/RS485 convertor.
Page 58
KIEN2032 Industrial Ethernet Switch User's Manual test computer 2. In this way, any character entered from the super terminal window of the test computer 2 should be displayed in the super terminal window of the test computer 1. The test of data 1 is normal.
The most typical networking mode of KIEN2032 is the redundant ring network. The KIEN2032 builds the optical fiber redundant ring network, as showed in the Figure ure 7-1. One switch is set as the central office device and others are set as remote. In case of breaking of the optical fibers, communication can be recovered within 300ms.
7-1 Optical Fiber Redundant Ring network of KIEN2032 7.2 System Configuration The KIEN2032 industrial Ethernet switches adopt integrated structure with the standard configuration of 3 10Base-T/100Base-TX Ethernet RJ-45 ports and 2 redundant 100Base-FX optical fiber ports are configured fixedly. The optical fiber interface can be customized to single mode/multi-mode.
Page 61
Chapter7 Networking Modes And System Configuration Table 7-1 Configuration Table for KIEN2032 Switch Model Switch Description 100Base-FX single mode optical fiber 2 uplink redundant KIEN2032-2S(A) interface and 2 RS232s and 1 RS485 data interface 100Base-FX single mode optical fiber 2 uplink redundant KIEN2032-2S(B)...
Appendix A Twisted -pair and Pin Distribution For the 10Base-T/100Base-TX, the twisted-pair should present two pair of wires. Each pair is differentiated by different colors. For instance, the one is green and the other is the green and white interleaved. There should be the RJ-45 connector at both sides of cables.
Page 64
KIEN2032 Industrial Ethernet Switch User's Manual cable and are connected to the pin 1, 2, 3 and 6 at the other end of the connection cable. If it is necessary to connect to the switches or hubs with MDI-X port, it needs to use the crossover wire.
Appendix B Type and Specificat ion of Cable The type and specification of cable is shown as Figure .B-1. Table B-1 Type and Specification of Cable Connect Cable Type Maximum Length Cat3, Cat4 and Cat5, 100ohm 100m (328 foot) 10Base-T RJ-45 100m (328 foot)...
Appendix C Glossary Terminology Explanation Twisted-pair standard of Cat3, Cat4 and Cat5 in IEEE specification for 10Base-T 10Mbps Ethernet Twisted-pair standard of Cat5 or above in IEEE specification for 100Base-TX 100Mbps Fast Ethernet Fast Ethernet which uses one pair of multi-mode or single mode optical 100Base-FX fiber to transmit.