Kenmore 11065202310 Installation Instructions Manual page 11

29" wide electric models
Table of Contents

Advertisement

Available languages

Available languages

Remove
center terminal
block
screw
(B).
Put direct
wire cable
through
the strain
relief.
The strain
relief
should
have a tight
fit with
the dryer
cabinet
and be in a horizontal
position.
Tighten
strain
relief
screw
against
the direct
wire cable.
if your
wiring
looks llke this:
4-wire
direct
connection:
Go to "4-Wire
Direct
Connection"
on this page.
if your wiring
looks llke this:
3-wire
direct
connection:
/]l]r_
Go to _"3-Wire
Direct
Connection"
on page
12
Connect
neutral
wire (white
or center)
(C) of power
supply
cord
to center
terminal
block
screw
(B). Tighten
screw.
3.
Connect
remaining
wires
Connect
remaining
wires to outer
terminal
block
screws.
Tighten
screws.
Finally,
reinsert
tab of terminal
block
cover
into slot of dryer
rear
panel.
Secure
cover
with
hold-down
screw.
Now,
go to "Venting
Requirements."
Dire¢_ Wire Connection
Direct
wire
strain
relief
4owire
Dire¢_ Wire Connection
iMPORTANT:
A 4-wire
connection
is required
for mobile
homes
and
where
local
codes
do not permit
3-wire
connections.
1. Prepare
your 4-wire
cable for direct
connection
Direct
wire cable
must have 5 ft. (1.52 m) of extra
length
so dryer
may
be moved
if needed.
Strip
5" (127 mm) of outer
covering
from
end of cable,
leaving
bare
ground
wire at 5" (127 mm).
Cut 11/2`' (38 mm) from
remaining
3 wires.
Strip insulation
back
1" (25 mm).
Shape
ends of wires
into
hooks.
Unscrew
the removable
conduit
connector
(A) and any
screws
from
a 3A"
(19 mm) UL listed
strain
relief.
Put the threaded
section
of the strain
relief
(C) through
the hole below
the terminal
block
opening
(B). Reaching
inside
the terminal
block
opening,
screw
the removable
conduit
connector
(A)
onto
the strain
relief
threads.
and neutral
wire
Remove
center
terminal
block
screw
(B). Remove
neutral
ground
wire
(E) from
external
ground
conductor
screw
(A).
11