Kenmore 11065202310 Installation Instructions Manual page 16

29" wide electric models
Table of Contents

Advertisement

Available languages

Available languages

Special
provisions
for
mobile
home
installations:
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home.
Terminate
the exhaust
vent outside.
Determine
vent
path:
[]
[]
[]
[]
[]
Determine
vent
length
and
elbows
needed
for
best
drying
performance:
[]
Use following
"Vent
System
Chart"
to determine
type
of vent
material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer
than
those specified
in "Vent
System
Chart."
Exhaust
systems
longer
than
those
specified
will:
[]
Shorten
life of dryer.
[]
Reduce
performance,
resulting
in longer
drying
times
and
increased
energy
usage.
Select
route that
will provide
straightest
and most direct
path
outdoors.
Plan installation
to use fewest
number
of elbows
and turns.
When
using elbows
or making
turns, allow
as much
room
as possible.
Bend vent gradually
to avoid
kinking.
Use as few
90 ° turns as possible.
The '"Vent System
Chart"
provides
venting
requirements
that
will help
achieve
best drying
performance.
Vent System Chart
Number
of
Type
Box/Iouvered
Angled
90 ° turns
of vent
hoods
hoods
or elbows
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6
m)
2
Rigid metal
44
ft. (13.4
m)
38 ft. (11.6 m)
3
Rigid
metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4
m)
12" rnin.
(305 ram)
Install
exhaust
hood
and
use caulking
compound
to seal exterior
wall
opening
around
exhaust
hood.
2.
Connect
vent to exhaust
hood
Vent must fit inside
the exhaust
hood.
Secure
vent to exhaust
hood
with
4" (102 mm) clamp.
Run vent to dryer
location
using straightest
path
possible.
Avoid
90 ° turns. Use clamps
to seal all joints.
Do not
use duct
tape,
screws,
or other fastening
devices
that
extend
into
interior
of vent to secure
vent, because
they can
catch
lint.
Cormec_ Ven_
1. Connect vent to exhaust outlet
Using
a 4" (102 mm) clamp,
connect
vent to exhaust
outlet in dryer.
Jf connecting
to existing
vent, make
sure vent is clean.
Dryer
vent
must
fit inside
dryer
exhaust
outlet and exhaust
hood.
Check
that vent is
secured
to exhaust
hood
with
a 4" (102 mm) clamp.