Hood Exhaust - GE JVM1650BB005 Installation Instructions Manual

Table of Contents

Advertisement

Installation
Instructions
HOOD EXHAUST
NOTE:
Read these
next two pages
only if you plan to vent your exhaust
to the
outside.
If you plan to recirculate
the air back into the room,
proceed
to page 6.
OUTSIDE
TOP EXHAUST
(EXAMPLE
ONLY)
The following
chart describes
an example
of one possible
ductwork
installation.
EQUIVALENT
NUMBER
EQUIVALENT
DUCT PIECES
LENGTH
x
USED
=
LENGTH
RoofCap
12 Ft.Straight Duct
(6" Round)
Rectangular-to-Round
TransitionAdapto¢
24 Ft.
x
(1)
12 Ft.
x
(1)
5 Ft.
x
(1)
=
24 Ft.
12 Ft.
5 Ft.
Equivalent l engthsof duct piecesare basedon actualtests and
reflect requirements for goodventing performance with anyvent hood.
Total Length
=
41 Ft.
* IMPORTANT:
If a rectangular-to-round
mmsition
adaptor is used, the bottom corners
of the damper
will have to be cut to fit, using the fin snips, in order to allow flee movement
of the dampeL
OUTSIDE
BACK EXHAUST
(EXAMPLE
ONLY)
The following
chart
describes
an example
of one possible
ductwork
installation.
DUCT PIECES
EQUIVALENT
LENGTH*
x
NUMBER
USED
Wall Cap
3 Ft.Straight Duct
31A " x 1O"Rectangular)
40 Ft.
3 Ft.
(1)
(1)
EQUIVALENT
LENGTH
40 Ft.
3 Ft.
(_
go° Elbow
10 Ft.
x
(2)
=
20 Ft.
Equivalent l engthsof duct piecesare basedon actual tests and
reflect requirements for goodventing performance with anyvent hood.
Total Length
=
63 Ft.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed
by leaving enough
space between the wall studs to accommodate
exhaust.
4