4. Snap the AP-6511E on to the mounted wall plate. Use the locking screw to secure the unit. This connection
does not require the use of tools or fastening hardware.
Once installed, connections are hidden from forward view, with only the physical infrastructure cables
(Ethernet and power) extending from the AP-6511E.
5. Cable the Access Point using a Power Injector solution (AP-PSBIAS-2P2-AFR) as described in the
following:
a. Connect an RJ-45 CAT5 Ethernet cable between the network data supply (host) and the Power
Injector's Data In connector.
b. Connect an RJ-45 CAT5 Ethernet cable between the Power Injector's Data & Power Out connector
and the AP-6511E Access Point.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and Access Point does
not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector
receives power as soon as AC power is applied. For more information, see
6. Verify the behavior of the AP-6511E Access Point LEDs. For more information, see
7. The AP-6511E is ready to configure. For information on basic Access Point device configuration, see
WiNG Express Access Point
Configuration.