Fetco CBS-2031ee User Manual page 11

Hide thumbs Also See for CBS-2031ee:
Table of Contents

Advertisement

Address
Description
60
Left Brew Valve
and
Flow Rate
61
Right Brew Valve
Flow Rate
CBS-2031ee/2032ee
CBS-2041ee/2042ee
64
Keypad Test
65
Relay Test
Warning: During these
tests, hot water may
be dispensed from
the va lve being tested.
67
Factory Use Only – Do not use.
Important! To save your changes, press and hold STOP until the display reads STO to exit programming
mode and return to operating mode.
Range
Default
0.35 – 2.24
1.48
If #59 is LTR
or
0.09 – 0.59
0.39
If #59 is GAL
0.09 – 0.59
0.40
If #59 is GAL
or
0.35 – 2.24
1.51
If #59 is LTR
0 - 1
0
0
Address
Description
90
Left or Single Brew Valve
91
Right Brew Valve
95
Fill Valve
96
Heater
(To protect the heaters, this test will work only if the tank is full.)
Press STOP to go back to address 65.
Press the lower batch button to exit the Relay Test.
11
Comment
Use this to compensate for minor discrepancies in
actual volume versus programmed volume. Set
lower to increase volume, higher to decrease
volume. The following formula can be used to
determine the correct setting:
ACTUAL VOLUME
X
PROGRAMMED VOLUME
Tests function of control panel switches.
Starting at the batch buttons, press each button
that is lit. The display will show the name of the
switch being pressed and the switch light will go
out. Brew switches are named S1, S2, S3, etc.
The left STOP switch must be pressed last, as
this will exit the test.
Tests the individual relays that control various
components.
0 - Skip relay test.
To start Relay Test, press top batch button –
display will read OFF.
Press power switch – display will read ON.
Press STOP to continue.
Use the batch buttons to turn each component
ON and OFF.
CURRENT
NEW
=
SETTING
SETTING