Temperature Settings

Parameter
Name
7
Water Temp. (°F)
7.1
ECO Mode
9
Brew at Set
Temperature
Parameter
Name
10
Enter Advanced
Settings &
Diagnostics
Important! To save your changes, press and hold STOP until the display reads STO to exit programming mode
and return to operating mode.

Advanced Settings and Diagnostics

Address
Description
50
Water Level
in Tank
51
Water Resistance
(KΩ)
53
Power Relay State
54
Water Level
Sensitivity
55
Tank Temperature
56
Brewer Model
Number
57
Reload Defaults
58
Temperature Scale
59
Water Volume Scale
CBS-2031ee/2032ee
CBS-2041ee/2042ee
Range
Default Setting
188°F - 206°F
OFF/ON
0 - 1
Range
Default Setting
0 - 1
Range
Default
0 - 1
0 – 200
0 – 1
LO - HI
LO
180°F - 208°F
31 – 41
or
32 - 42
0 - 1
0
F or C
F
GAL or LTR
LTR
GAL or LTR
GAL
10
Comment
Inside tank. Will be slightly lower at
200°F
spray head. To display in ° Celsius,
see # 58 in Advanced Settings.
OFF
ON= After 1 hour passes without
brewing, the temperature setting will
automatically be lowered by 30°F, and
the display will read ECO. Press STOP
to resume normal heating.
The hot water faucet may be used
without affecting the ECO cycle,
however the temperature of the
dispensed water may be lower than
desired.
1
0=Will brew at any temperature.
1=Will brew only at set temperature.
Note: Changes will not take effect until
the next brew cycle is completed.
Comment
0
0 = Skip Advanced Settings &
Diagnostics. Loop back to start of
batch programming cycle.
1 = Enter Advanced Settings &
Diagnostics.
Press STOP to continue
Comment
Tests if water is touching probe.
0 = Tank is less than full
1 = Tank is full
Displays the electrical resistance of the water in
kilohms as measured between the water level
probe and the tank. If greater than 200, or if the
tank is not full, the display will read – – – .
To check the function of the power relay, press the
power button repeatedly. The display should
toggle between 0 and 1.
LO – 0 to 50 KΩ
HI – 50 to 130 KΩ
If water resistance (address 51) is greater than 25
KΩ, set on HI to prevent unwanted filling of tank.
Displays current tank temperature.
Must be set for the correct model number of the
brewer: 31 for CBS-2031ee, 32 for CBS-2032ee,
41 for CBS-2041ee, 42 for CBS-2042ee.
Changes all settings to default factory settings.
0 = Do not reload defaults
1 = Reload all default settings
If 1 is selected, you must advance to the next
address for this change to take effect.
Does not change address 56 – model number.
F = Fahrenheit
C = Celsius
GAL = Displays volume in gallons
LTR = Displays volume in liters

Hide quick links: