FUEL CONVERSION
Control Board
Figure 75
10. Replace conversion cap with new cap supplied in kit.
Gently remove with small fl at screwdriver. Figure 76
Convert Control Board
11. Reinstall A/C module and control board in reverse or-
der.
12. Using open end wrenches of 5/8" and 3/4", loosen
nuts secured to the injectors through the opening on
the lenses removed earlier. Pull fl ex line away. Re-
place injectors with injectors provided in kit. Refer to
Table 1 for correct injector sizes. Injectors are differ-
ent in size and specifi c to each burner.
13. For conversion to LP: Unscrew three (3) air shutters
through lens opening and discard. Figure 77. NOTE:
Replace screws.
Table 1
Fuel Type
Burner Orifi ce
LP
Burner Orifi ce
Natural
20306745
A/C Module
Remove
Screw
Orifi ce Size
Left
Middle Right
1.25 mm 1.2 mm
#56
#44
#43
#45
Remove Air
Shutter
Figure 77 -
Remove Air Shutters - Conversion to LP
Figure 78 -
Install Air Shutters - Conversion to Natural Gas
For conversion to Natural gas: Install new air shut-
ters provided and adjust to 1/8" opening. Figure 78
14. Reassemble fl ex lines to injectors and tighten nuts.
15. Remove the top of the pilot assembly by pulling back
slightly on the C-clamp (Figure 79) and pulling straight
up on the hood. Remove the pilot orifi ce using a fl at-
blade screwdriver and replace with new pilot orifi ce
provided in kit.
16. Replace pilot hood and C-clamp.
1. Partially disengage C-clamp
Figure 79
VWDV70 Series Gas Fireplace
Replace Screw
KT560
Install Air Shutters
to 1/8" Open
2. Pull up on hood to remove
47