Symptom
Battery icon on LCD on transmitter
LCD display is blank
LCD display shows "funny" display
Appliance does not come on
Blower is not on after the fi replace
is turned on
20306745
Figure 73
TROUBLESHOOTING
Causes
Low Battery
Low Battery
Low Battery
The transmitter did not match with the
receiver.
Transmitter measures temperature
exceeding 99°F and shows "HI" on LCD.
Distance between the transmitter and
receiver is more than 30 feet.
Blower setting is off.
Blower delay setting is set too high.
VWDV70 Series Gas Fireplace
Action
Replace batteries. Change batter-
ies every 6 months.
Check battery installation or replace
batteries.
Reset the transmitter (see "Reset-
ting the Transmitter" setting)
Make sure the transmitter has
learned to the receiver.
Move transmitter to a cooler place
and wait until temperature drops
below 99°F.
Make sure the opening distance is
less than 30 feet.
Press FAN key to select fan speed
desired.
Press and hold FAN key to set
desired ON/OFF delays. This is
done in minutes.
45