Through Frame Crank; Extension W/ Pin; Crank Handle - Jayco 2016 PINNACLE User Manual

Towables
Table of Contents

Advertisement

S
S
lideout
yStemS
The controller that has malfunctioned should have a flashing red LED indicating a hall
2.
signal fault (will flash 8 or 9 times).
3.
Press the "mode button" six times quickly, then press a seventh time and hold for
approximately 5 seconds.
The red and green LED's will begin to flash indicating you are in override mode.
4.
Release the mode button.
5.
Use either a wall switch, or one of the slide room switches located on the command
center panel (depending on the slideout).
RETRACT (printed next to the switch) and hold it until the unit comes in completely.
6.
This will allow you to get the recreation vehicle to a service center to have the slideout
malfunction diagnosed.
During this override procedure the motors are not synchronized. Visually
watch the room, and if one side is moving significantly slower than the other
(or not at all), immediately stop and call your dealer or Jayco Customer
Service.
If the system stalls our before reaching end of stroke OR if the room does not
close and seal tightly, call your dealer or Jayco Customer Service.
Manually pushing in the slideout
1.
Locate the slideout system controller (refer to previous Step 1; locating the system
controllers).
2.
Unplug motor 1 and motor 2 connectors at the bottom of the slideout controller. This
releases the motor brakes for each motor.
3.
The slideout room can now be manually pushed in. Larger rooms may require several
people to push or pull them.
4.
Keep both sides of the slideout relatively even while pushing/pulling.
60
Press the switch toward the word IN or

