Rs485 Bus Faq - IC Realtime PTZ2300SIR User Manual

Ir speed dome
Hide thumbs Also See for PTZ2300SIR:
Table of Contents

Advertisement

conform to RS485 Bus standard. When the distances between devices are too long, the signal reflection
occurs and anti-jamming decreases, thus the signal reliability becomes very low. You can see speed dome
is not under control or speed dome is running automatically and can not stop.
In this situation, we recommend RS485 distributor. This device can turn star type connection into the
connection that conforms to RS485 bus industry standard, which can avoid the above mentioned problems
and enhance communication reliability. See Figure 7-4.

7.5 RS485 Bus FAQ

Phenomenon
Possible Reasons
Speed dome
can run self-
diagnosis but I
can not control
it.
I can control
the speed
dome but is not
smooth
Host address(baud rate) and
speed dome address(baud rate)
are not match;
Positive and negative end of
RS485 Bus are misconnected;
Connection cable is loose;
RS485 Bus connection are cut
off;
RS485 Bus connection are not
good;
One RS485 bus is off;
The distance between host and
speed dome is too far;
Parallel connected too much
speed domes.
Figure 7-3
Figure 7-4
Solution
Modify host or speed dome setup ;
Switch RS485 positive end and
negative end;
Fix connection cable firmly;
Replace RS485 Bus.
Connect RS 485 Bus again;
Replace RS485 Bus;
Add terminal matching resistance;
Add RS485 distributor.
33

Advertisement

Table of Contents
loading

Table of Contents