Alarm Setup - IC Realtime PTZ2300SIR User Manual

Ir speed dome
Hide thumbs Also See for PTZ2300SIR:
Table of Contents

Advertisement

SWITCH ZOOM: It is the zoom rate of the near light, and far light.
HEIGHT: It is the speed dome installation height from the ground.
IRLIGHT CTRL: There are three options: Zoom rate has the higher priority, height has the higher priority,
manual.
NEAR LIGHT: It is the medium and near light brightness.
FAR LIGHT: It is the far light brightness.
IR LIGHT COMPENSATION: It is the whole compensation level of the IR light.
4.4.6

Alarm Setup

ALARM NO
ACTION
CONTACT
PRESET
AUTO SCAN
CRUISE
RELAY OUT
RESET DELAY
SAVE
BACK
EXIT
Move the cursor to highlight ALARM SETTING button and then click confirm button.
ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 7. Please use the left/right
button on the keyboard or in the speed dome terminal menu to set.
ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOURING functions.
Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
CONTACT:You can set system activation operation once alarm occurred. There are two alarm signal
mode: normal open (N/O) and normal closed (N/C). Please use the left/right button on the keyboard or
in the speed dome terminal menu to set.
PRESET NO:Please use the left/right button on the keyboard or in the speed dome terminal menu to
set. The camera will turn to the specified preset to monitor after alarm occurs.
AUTO SCAN:Please use the left/right button on the keyboard or in the speed dome terminal menu to
set. The camera will begin auto scan after alarm occurs.
CRUISE:Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
The camera will begin auto cruise when alarm occurs.
RELAY OUT: Here is to set relay alarm mode and reset time. There are several options:
off/1→5S/2→5S/1&2→5S.
1→5S:1 means the first relay output.5S means the relay will reset automatically in five seconds
after alarm occurs.
1&2→5S:1&2 means the first relay and the second relay work at the same time.
RESET DELAY: Here is for you to set alarm reset time. Please use the left/right button on the keyboard
or in the speed dome terminal menu to set: 3 seconds/10 seconds/30 seconds/60 seconds /120seconds.
The dome will go back to previous setup after alarm acknowledgement.
SAVE:Move the cursor to SAVE and then click confirm button to save current setup.
BACK: Go back to previous menu.
:01
:NONE
:N/O
:001
:001
:001
:OFFS
:3S
28