Eiki LC-WXL200 Service Manual page 60

Hide thumbs Also See for LC-WXL200:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No. Item
4
Press Sensor Calibration Log
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
1
Fan 1 Max Adjust (DAC)
2
Fan 2 Min Adjust (DAC)
3
Fan 2 Max Adjust (DAC)
4
Fan 3 Min Adjust (DAC)
5
Fan 3 Max Adjust (DAC)
6
Fan 4 Min Adjust (DAC)
7
Fan 4 Max Adjust (DAC)
8
Fan 5 Min Adjust (DAC)
9
Fan 5 Max Adjust (DAC)
10
Fan 6 Min Adjust (DAC)
11
Fan 6 Max Adjust (DAC)
12
Fan 7 Min Adjust (DAC)
13
Fan 7 Max Adjust (DAC)
252
Fan Option
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3 Manual Voltage
6
Fan4 Manual Voltage
7
Fan5 Manual Voltage
8
Fan6 Manual Voltage
9
Fan7 Manual Voltage
10
Angle Data A
11
Angle Data B
12
Press Data
253
Fan Temp Error Setting
5
Temp A Warning (Normal)
6
Temp B Warning (Normal)
7
Temp C Warning (Normal)
8
Temp B-A Warning (Normal)
9
Temp C-A Warning (Normal)
10
Temp A Warning (Eco)
11
Temp B Warning (Eco)
12
Temp C Warning (Eco)
13
Temp B-A Warning (Eco)
14
Temp C-A Warning (Eco)
15
Temp A Warning Offset (Temp)
16
Temp B Warning Offset (Temp)
17
Temp C Warning Offset (Temp)
18
Temp B-A Warning Offset (Temp)
19
Temp C-A Warning Offset (Temp)
20
Temp A Warning Offset (Time)
21
Temp B Warning Offset (Time)
22
Temp C Warning Offset (Time)
23
Temp B-A Warning Offset (Time)
24
Temp C-A Warning Offset (Time)
254
Fan Control Range Setting (Temp/Spinning)
16
Normal Fan Control Min Temp
17
Normal Fan Control Max Temp
Function
Calibration LOg
0: Excuted and Adquate Offset Value
10:Out of Range (Mini)
20: Out of Range (Max)
99: Not executed
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Angle Data A (Read only)
Angle Data B (Read only)
Air Pressure Data (Read only)
(Memorized)
Temp A (Room) to judge the Temp Error at Normal
Temp B (Lamp) to judge the Temp Error at Normal
Temp C (Panel) to judge the Temp Error at Normal
Temp B - A (Filter Clogged) to judge the Temp Error at Normal
Temp C - A (Filter Clogged) to judge the Temp Error at Normal
Temp A (Room) to judge the Temp Error at Eco
Temp B (Lamp) to judge the Temp Error at Eco
Temp C (Panel) to judge the Temp Error at Eco
Temp B - A (Filter Clogged) to judge the Temp Error at Eco
Temp C - A (Filter Clogged) to judge the Temp Error at Eco
Temp Warning Offset (Temp)
Time Warning Offset (Time)
Temp Sensor Control Start/End Temp at Normal
Range
-
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-6
0-1
0-255
0-255
0-255
0-255
0-255
0-255
0-255
-
-
-
Normal
30-100
47
30-100
71
30-100
65
0-100
100
0-100
100
30-100
48
30-100
71
30-100
65
0-100
100
0-100
100
0-100
0-100
0-100
0-100
0-100
0-40
0-40
0-40
0-40
0-40
Normal
20-100
25
20-100
37
-55-
Initial
Note
99
* Fan voltage adj.
84
237
83
240
40
244
40
230
41
232
43
233
39
229
0
0
100
100
100
100
100
100
100
-
-
-
Ceiling
Top
Bottom
48
46
46
73
71
71
67
65
64
100
100
100
100
100
100
48
46
46
71
70
69
65
63
63
100
100
100
100
100
100
10
11
13
11
13
30
25
30
15
15
110°
70°
Top
Normal
Ceiling
Bottom
290°
250°
Ceiling
Top
Bottom
26
25
26
37
36
36