4
3
2
Turn on
1
alternately
1
or
4
3
2
Turn on
1
alternately
Off
On
4
3
2
1
4
3
2
1
2-8

Diagnosis mode

Diagnosis mode
Recoverable errors of battery pack or
battery charger
If the battery pack or battery charger has the
errors, the following procedure can be used to
access the error diagnosis mode and confirm
the details regarding the error of the battery
pack or battery charger.
1. If there is an error when the battery capacity
indicator button "
is pushed or connect the battery charger,
the battery capacity indicator lamps [1]/[3]
and [2]/[4] turn on alternately, or the lamps
[1]/[2] and [3]/[4] turn on alternately.
When the battery capacity indicator lamps
turn on alternately, the residual battery
capacity is not displayed.
2. Hold down the battery capacity indicator
" 1 for 10 seconds.
button "
3. The lighting display of the battery capacity
indicator lamps indicates the error of the
battery pack or battery charger.
TIP
• If the battery pack or battery charger is
operating normally, the battery capacity
indicator lamps indicate the residual battery
capacity.
• If there are multiple errors, only the latest
error will be displayed.
• The error diagnosis mode can be accessed
whether the battery charger is connected or
disconnected.
ELEC
" 1 on the battery pack
+