Sample Interval
Sample Type
Rising Threshold
Falling Threshold
Rising Event
Falling Event
Owner
Buttons
: Click to apply changes.
The Page includes the following fields:
Object
Index
Sample Port
Sample Variable
Sample Interval
Sample Type
Rising Threshold
Falling Threshold
Rising Event
received andtransmitted where the number of octets fall within the specified
range (excluding framing bits but including FCS octets).
Sample interval (1–2147483647)
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly (default).
Delta: Calculate the difference between samples.
Rising threshold value (0–2147483647)
Falling threshold value (0–2147483647)
Event to fire when the rising threshold is crossed
Event to fire when the falling threshold is crossed
Specify an owner for the alarm
Figure 4-14-6: RMON Alarm Status Page Screenshot
Description
Indicates the index of Alarm control entry.
Display the current sample port.
Display the current sample variable
Display the current interval
Display the current sample type
Display the current rising threshold
Display the current falling threshold
Display the current rising event
301
User's Manual of GSD-1002M