In a steady wind flow, Bernoulli's Law applies:
where:
Air density in kg/m
ρ
Wind velocity in m/s
v
p
Static pressure in Pa
and where:
denotes the dynamic pressure and p the static pressure. The total of these pressures
gives the total pressure.
Wind load against a surface makes the dynamic pressure become a static pressure
against the surface. The magnitude of this static pressure is determined by, amongst
other things, the shape of the surface and its angle to the wind direction.
The portion of the dynamic pressure that becomes a static pressure on the surface
(p
) is determined by what is known as a stress concentration factor:
stat
If ρ is 1.23 kg/m
pressures in the wind flow:
Publ. No. T559382 Rev. a358 – ENGLISH (EN) – June 23, 2009
3
3
(density of air at +15°C (+59°F)), this gives the following local
16 – Introduction to building thermography