Port Sequential - Planet WGSD-10020 Series User Manual

L2+ gigabit ethernet managed switch
Hide thumbs Also See for WGSD-10020 Series:
Table of Contents

Advertisement

Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is
to provide information about the maximum power required by the PD during operation. However, to improve power management
at the PSE, the PD provides a signature about Class level.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes.
A PD will return to Class 0 to 4 in accordance with the maximum power draw as specified by
Class
Usage
Default
0
Optional
1
Optional
2
Optional
3
Optional
4

4.16.4 Port Sequential

This page allows the user to configure the PoE Ports started up interval time. The PoE Port will start up one by one as
4-16-3
shows.
Figure 4-16-3: PoE Port Sequential Power Up Interval Configuration Screenshot
The PoE port will start up after the whole system program has finished running.
Range of maximum power used by the PD
12.95 watts (or to 15.4 watts for AF mode)
25.5 watts (or to 30.8 watts for AT mode)
0.44 to 3.84 watts
3.84 to 6.49 watts
6.49 to 12.95 watts (or to 15.4 watts)
12.95 to 25.50 watts (or to 30.8 watts)
Table 4-16-2 Device Class
User's Manual of WGSD / WGSW Layer 2+ Series
Mid power or High power
322
Table 4-16-2.
Class Description
Very low power
Low power
Mid power
High power
Figure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wgsw-20160hpWgsw-24040 series

Table of Contents