Connecting Speakers
Connecting Speakers
Before connecting speakers to your P -935N unit, be sure to disconnect the
C power cable. Make certain that the total impedance should not be less than
the rated impedance indicated.
For 4
low-impedance speakers, connect in parallel, with the negative (-)
connectors to the COM terminal and the positive (+) connectors to the 4
See Figure 2-1 below.
For 8
low-impedance speakers, connect in parallel, with the negative (-)
connectors to the COM terminal and the positive (+) connectors to the 8
See Figure 2-2 below.
FOR 4
TERMIN L
For high-voltage distributed systems, connect with matching transformer as per Figures 2-3 and 2-4 below.
Be certain that the total impedance does not equal less than the rated impedance.
FOR 70V TERMIN L
Be sure that total impedance is not less than rated impedance.
(Figure 2-1)
(Figure 2-3)
PUBLIC DDRESS MPLIFIER
terminal.
terminal.
FOR 8
TERMIN L
(Figure 2-2)
FOR 100V TERMIN L
Be sure that total impedance is not less than rated impedance.
(Figure 2-4)
7