Outdoor Sensor Bad
Displayed when an error has been detected with the outdoor
sensor. This error must be corrected by servicing the zone panel
outdoor sensor. If the outdoor sensor is not operating correctly, the
zone panel will not use outdoor balance point control for
heating calls.
Invalid Address on Expansion Panel
Displayed when an invalid address has been set on an expansion
panel. This message will appear when an expander is powered up
and wired to the communication terminals. To locate the expander
panel with the invalid address, view the expander panel status LED.
The status LED will be flashing red.
Duplicate Address on Expansion Panel
Displayed when a duplicate address has been set on an expansion
panel. This message will appear when an expander is powered up
and wired to the communication terminals. To locate the expander
panel with the duplicate, view the expander panel status LED.
The status LED will be flashing red.