The configuration settings must be properly set in order for this zone panel to operate correctly. The Installer
Settings will automatically adjust so that settings that do not apply to this installation will be skipped.
All settings are shown below with comments.
No. Installer Setting
(
Notes follow table)
1
System Type
2
Thermostat Type
3
1st Stage Fan Control
4
Auxiliary Fan Control
5
Reversing Valve Control
6
Auxiliary Stage
Compressor Heat
Lockout
7
Zone Fan Purge Time
Supply Air Sensor Control SA SENS
8
Plenum High Limit Cutout PLENUM
9
10 Plenum Low Limit Cutout
Display
Factory
Indicator
Default
SYSTEM
SSC
TSTAT TP CON
FAN 1
GAS
AUX FAN
EL
REV VAL
O
COMP LOC
OFF
PURGE
90
YES
170
SET HI LIMIT
PLENUM
45
SET LO LIMIT
Setting
Comments
Options
(More information follows this table)
SSC
Select for 1H/1C conventional equipment [Note 9]
MSC
Select for 2H/1C up to 3H/2C conventional equipment [Note 9]
SSH
Select for 1H/1C Heat Pump equipment
MSH
Select for 2H/1C up to 4H/2C Heat Pump Equipment
CON
Select for all thermostats conventional type
HP
Select for all thermostats heat pump type
GAS
Select for 1st Stage fan controlled by equipment
EL
Select for 1st Stage fan controlled by panel
GAS
Select for auxiliary fan controlled by equipment
EL
Select for auxiliary fan controlled by panel
O
Select for cool active reversing valve
B
Select for heat active reversing valve [Note 7]
OFF
Select for Compressor runs with Auxiliary Heat Call
ON
Select for Compressor is off with Auxiliary Heat Call
300
Select for 300 second purge into calling zone at call end
240
Select for 240 second purge into calling zone at call end
180
Select for 180 second purge into calling zone at call end
120
Select for 120 second purge into calling zone at call end
90
Select for 90 second purge into calling zone at call end
60
Select for 60 second purge into calling zone at call end
30
Select for 30 second purge into calling zone at call end
0
Select for no purge into calling zone at call end
YES
Select for Active Supply Air Sensor
NO
Select for Inactive Supply Air Sensor [Note 5]
100 to 180 Select the maximum Supply Air Temperature the system
can reach before shutting off all heating stages [Note 6]
30 to 60
Select the minimum Supply Air Temperature the system
can reach before shutting off all cooling stages [Note 6]
11