Kyocera FS-C2026MFP Service Manual page 73

Hide thumbs Also See for FS-C2026MFP:
Table of Contents

Advertisement

Item No.
U641
Setting communication time 2
Description
Sets the time-out time for fax transmission.
Purpose
To improve transmission performance for international communications mainly.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
T0 Time Out
T1 Time Out
T2 Time Out
Ta Time Out
Tb1 Time Out
Tb2 Time Out
Tc Time Out
Td Time Out
Setting the T0 time-out time
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Depending on the quality of the exchange, or when the auto select function is selected at the
destination unit, a line can be disconnected. Change the setting to prevent this problem.
1. Change the setting using the cursor left/right keys.
Description
T0 time-out time
2. Press the start key. The value is set.
Setting the T1 time-out time
Sets the time before receiving the correct signal after call reception. No change is necessary for
this maintenance item.
1. Change the setting using the cursor left/right keys.
Description
T1 time-out time
2. Press the start key. The value is set.
Description
Description
Sets the T0 time-out time.
Sets the T1 time-out time.
Sets the T2 time-out time.
Sets the Ta time-out time.
Sets the Tb1 time-out time.
Sets the Tb2 time-out time.
Sets the Tc time-out time.
Sets the Td time-out time.
1-3-39
Setting range
Initial setting
30 to 90 s
56
Setting range
Initial setting
30 to 90 s
36
2KW/2KX