Code
Contents
4202
Laser output error (cyan)
The pin photo signal is not
output from PD PWB C for
one second while laser is
emitted.
4203
Laser output error
(magenta)
The pin photo signal is not
output from PD PWB M for
one second while laser is
emitted.
4204
Laser output error (yellow)
The pin photo signal is not
output from PD PWB Y for
one second while laser is
emitted.
4600
LSU cleaning motor error
When the LSU cleaning motor
is driven, the motor over-cur-
rent detection signal is
detected continuously for 50
times (5 s) at 100 ms inter-
vals.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
APC PWB C and engine PWB (YC32)
Defective APC
Replace the laser scanner unit CY (see
PWB C.
page 1-5-44).
Defective PD PWB
Replace the laser scanner unit CY (see
C.
page 1-5-44).
Defective engine
Replace the engine PWB (see page 1-5-26).
PWB.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
replace the cable.
contact in the con-
nector.
APC PWB M and engine PWB (YC31)
Defective APC
Replace the laser scanner unit KM (see
PWB M.
page 1-5-44).
Defective PD PWB
Replace the laser scanner unit KM (see
M.
page 1-5-44).
Defective engine
Replace the engine PWB (see page 1-5-26).
PWB.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
APC PWB Y and engine PWB (YC32)
Defective APC
Replace the laser scanner unit CY (see
PWB Y.
page 1-5-44).
Defective PD PWB
Replace the laser scanner unit CY (see
Y.
page 1-5-44).
Defective engine
Replace the engine PWB (see page 1-5-26).
PWB.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
LSU cleaning motor and engine PWB
(YC36)
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushes and
tem of the LSU
gears. Check for broken gears and replace if
cleaning motor.
any.
Defective LSU
Replace the LSU cleaning motor.
cleaning motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-26).