Connector
Pin
YC101
1
LIVE
Connected to
2
NEUTRAL
AC inlet and
main power
switch
YC102
1
NEUTRAL
Connected to
2
LIVE
fuser heater
YC103
1
+24V1
Connected to
2
GND
relay PWB
3
GND
4
GND
5
GND
6
+24V2
7
+24V2
8
+24V2
9
+24V2
10
PSSLEEPN
11
ZCROSS
12
RELAY
13
HEATRE1
YC104
1
+24V1
Connected to
2
N.C
interlock
3
+24V2
switch
YC105
1
+24V1
Connected to
2
GND
main PWB
3
GND
4
+5V1
Signal
I/O
I
120 V AC
220-240 V AC
I
120 V AC
220-240 V AC
O
120 V AC/0 V
220-240 V AC/0 V
O
120 V AC
220-240 V AC
O
24 V DC
-
-
-
-
-
-
-
-
O
24 V DC
O
24 V DC
O
24 V DC
O
24 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Zero-cross signal
0/3.3 V DC
I
I
0/3.3 V DC
O
24 V DC
-
-
I
24 V DC
O
24 V DC
-
-
-
-
O
5 V DC
Voltage
AC power input
AC power input
FH: On/Off
AC power to FH
24 V DC power to RYPWB
Ground
Ground
Ground
Ground
24 V DC power to RYPWB (via ILSW)
24 V DC power to RYPWB (via ILSW)
24 V DC power to RYPWB (via ILSW)
24 V DC power to RYPWB (via ILSW)
Sleep mode signal: On/Off
Relay signal
FH: On/Off
24 V DC power to ILSW
Not used
24 V DC power from ILSW
24 V DC power to MPWB
Ground
Ground
5 V DC power to MPWB