12
3.12 VIEW ALARM HISTORY.
1. Enter the View Alarm History Mode.
Press
,
Any Zone Inputs that had an alarm during the last Armed period will be displayed on the Zone
Lamps. Press
3.13 VIEW FAULT HISTORY.
1. Enter the View Fault History Mode.
If the <FAULT> Lamp is On, or has been On, and you wish to view the cause of the Fault:
Press
,
Any System Inputs that have had an alarm during the last five Armed periods will be displayed on
the Zone Lamps in the following manner: Zone Lamp Flashing: System Input currently in alarm.
Press
to exit.
FAULT ANALYSIS LAMPS
LAMP
1
AC Fail.
2 Low battery.
3 Cabinet Tamper.
4 Siren monitor.
5 PWR fuse.
6 Battery fuse.
7 Comms fail.
8 System reset.
9 Keypad lockout.
10 Zone self test fail.
11 Keypad Medical.
12 Keypad Panic.
13 Keypad Duress.
14 Keypad Fire.
,
.
to exit.
,
.
EXPLANATION / ACTION
AC Mains power to the system has been interrupted and the system is
operating on backup battery power. Check that the AC supply for the system
is present and is turned on. If you cannot rectify the problem, call for service.
Battery voltage is too low to provide backup power if AC fails.
Call for service.
Interference with the equipment cabinet. Call for service.
Siren speaker is disconnected. Call for service.
Power fuse is blown. Call for service.
Backup Battery fuse is blown. Call for service.
System has failed to report. Call for service.
All power to the system has been interrupted.
Enter: PIN Code, <OFF> on the Terminal keypad to Clear.
You should reset the Time and Date. (NEXT 33) See page 24.
5 Invalid PIN codes in a row have been attempted.
You must now wait for the Keypad Lockout time to expire.
View the Zone Self Test History, NEXT 14.
Keypad Medical Alarm (7 & 9) has been activated.
Keypad Panic Alarm (1 & 3) has been activated.
A Duress PIN code has been entered on a Terminal keypad.
Keypad Medical Alarm (4 & 6) has been activated.
Version 2.02 December-2002
Zone Lamp ON:
System Input has had an alarm.