( 9 ) Removing and replacing the blower fan / blower fan motor
Note: The following procedure can be performed without removing the blower fan holder.
① Remove the right case.
→ ( Reference : Removing the right
case )
② Remove the blower fan holder
setscrews ( 3 ) to remove the blower
fan holder.
③ Remove the blower fan setnut ( 1 ) to
remove the blower fan.
→ ( Removing and replacing the
blower fan )
※ The blower fan setscrew is a
left-hand screw.
④ Remove the holding plate setscrews
( 4 ) to remove the blower fan motor.
→ ( Removing and replacing the
blower motor )
< Points at reassembly >
When installing the blower fan / blower
fan motor, set the lead wires toward
the top of the unit.
( 10 ) Removing and replacing the stepping motor
① Remove the right case.
→ ( Reference : Removing the right case )
② Remove the stepping motor set screws ( 2 ) to remove
the stepping motor.
→ ( Removing and replacing the stepping motor )
( 11 ) Removing and replacing the rotor motor
① Remove the right case.
→ ( Reference : Removing the right case )
② Remove the blower fan holder setscrews ( 3 ) to remove
the blower fan holder.
③ Remove the rotor motor setscrews ( 2 ) , and lift up the
case with the screws to remove them. Remove the
rotor motor.
→ ( Removing and replacing the rotor motor )
< Points at reassembly >
Put the rotor motor in the motor case,
and mount it on the frame. Engage it
with a gear of the zeolite at this point.
Blower fan
holder
Blower fan
holder
setscrew
Holding plate setscrews
Holding plate setscrews
Stepping
motor
setscrews
Blower fan
holder
Blower fan
holder
setscrew
Motor case
Rotor motor setscrews
Blower fan setnut
Blower fan
holder
setscrews
Blower fan
Holding
plate
Blower fan motor
Stepping motor
Motor case
Rotor motor
Blower fan
holder
setscrews
Zeolite
39