Mitsubishi MJ-EZ6CX-S1-IT Service Manual page 24

2010
Table of Contents

Advertisement

Display
A1
A2
Error code
Frequency
Content
RAM error
determination error
( When it is reset. )
Microcomputer
Microcomputer
( IC1 ) failure
( IC1 ) failure
Cause
→ Replace power
→Replace power
/
control board
control board
Remedy
Part name
Conditions
Connector
Check
terminals
Normal
value
A3
A6
Failure of photo
Frequency
interrupter
Watch dog
determination error
for dryer fan
error
( During operation )
(open)
Microcomputer
Microcomputer
Damage to
( IC1 ) failure
( IC1 ) failure
photo interrupter
→Replace power
→Replace power
control board
control board
A9
E2
E3
Short circuit
Disconnection
of room temp.
of room temp.
thermistor
thermistor
( 1 ) Disconnection of
( 1 ) Failure in soldering
temp./humidity
of sensor board
sensor lead wire
( 2 ) Short circuit of
( 2 ) Failure in soldering
connector pins ( P9)
of sensor board
( 3 ) Connector contact
failure
Room temp. / humidity sensor
Remove P9
P10
Between pin3 and pin4
47k- 51k
Ω
E4
E5
Disconnection
Short circuit
Disconnection
of heater
of heater
of frame
thermistor
thermistor
thermistor
( 1 ) Contact failure
( 1 ) Contact failure of
( 1 ) Contact failure
of operation control
operation control
of operation control
board
board connector
board
( 2 ) Disconnection
( 2 ) Short circuit of
( 2 ) Part failure
of lead wire
lead wire
( 3 ) Part failure
( 3 ) Part failure
Frame・heater thermistor
Remove P11 and P13
Between terminals
180
k
- 500k
Ω
E6

Hide quick links: