INSTALLATION OF INDOOR UNIT
Console Installation
• Select the terminal of Selector-SW from [C position]
to [F position].
Cutting a hole and mounting the Installation plate
• When installing the rear piping, determine the pipe
hole position, drill the pipe hole (∅80 mm) at a slight
downward slant to the outdoor side.
• For mounting of the Installation plate (1), use the
Paper pattern, which is inside the package box cover.
1093
742
Floor
5 mm dia. hole
Clip anchor
(local parts)
CAUTION
Failure to firmly install the unit may result in personal
injury and property damage if the unit falls.
• In case of block, brick, concrete or similar type walls,
make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate Mounting screws (4).
NOTE :
• Secure four corners and lower parts of the Installation
plate (1) with 6 to 8 mounting screws to install it.
375 mm
or more
140
Rear piping hole ∅80
Anchor bolt
Projection
15 mm or less
(4) Mounting screw
∅4 x 25 s s s s s
Install the indoor unit
• Install the Installation plate (1) at the wall according to
the Paper pattern.
• Hang the indoor unit on the hooks of the Installation
plate (1).
• Fix the lower portion of the indoor unit with Mounting
screws (4) (2 places).
(4) Mounting screw
Condition for installation
• The unit must not decline more than 15 mm in either
axis.
15 mm
Piping and Drain Hose Installation
• The piping direction can
be the following 3 ways
with the Drain hose.
• Each piping direction
should be connected
with the Flexible pipe (5).
• Cut or remove the
determined direction
slit or cover.
Cover for
side piping
9
Indoor unit
Hook
(1) Installation
plate
(4) Mounting screw
Rear piping
Side piping
Bottom piping
Slit for upper
piping
Cover for rear
upper piping