Toshiba RAV-SM562MUT-E Installation Manual
Toshiba RAV-SM562MUT-E Installation Manual

Toshiba RAV-SM562MUT-E Installation Manual

4-way air discharge cassette type
Hide thumbs Also See for RAV-SM562MUT-E:

Advertisement

AIR CONDITIONER
CLIMATISEUR
KLIMAGERÄT
CONDIZIONATORE D'ARIA
AIRE ACONDICIONADO
AR CONDICIONADO
AIRCONDITIONER
ÊËÉÌÁÔÉÓÔÉÊÏ
<4-Way Air Discharge Cassette Type>/<Type cassette à 4 voies de soufflage>
<4-Wege-Belüftungskassette>/<Tipo a cassetta con scarico d'aria a 4 vie>
<Modelo de casete de distribución de aire de 4 vías>/<Descarga de ar tipo cassete de 4 vias>
<Model voor inbouw in plafond met 4 uitblaasopeningen>/<ÅêñïÞ áÝñá 4-Äéåõèýíóåùí Ôýðïõ ÊáóÝôáò>
Heat Pump Model/Modèle à thermopompe
Geräte mit Heizung/Modello con pompa di riscaldamento
Modelo con bomba de calor/Modelo de bomba térmica
Model met warmtepomp/ÌïíôÝëï ìå Áíôëßá Èåñìüôçôáò
Indoor Unit/Unité intérieure
Raumeinheit/Unità interna
Unidad interior/Unidade interior
Binnenunit/ÅóùôåñéêÞ mïíÜäá
RAV-SM562MUT-E
Please read this Installation Manual carefully before installing the Air Conditioner.
• This Manual describes the installation method of the indoor unit.
• For installation of the outdoor unit, follow the Installation Manual
attached to the outdoor unit.
Veuillez lire attentivement ce Manuel d'installation avant d'installer le climatiseur.
• Ce manuel décrit la procédure d'installation de l'unité intérieure.
• Pour installer l'unité extérieure, reportez-vous au Manuel d'installation fourni avec
l'unité extérieure.
Bitte lesen Sie dieses Handbuch sorgfältig, bevor Sie mit der Installation des Klimagerätes beginnen.
• In diesem Handbuch wird die Installation der Raumeinheit beschrieben.
• Um die Außeneinheit zu installieren, folgen Sie den Anweisungen in dem Handbuch, das der Außeneinheit beiliegt.
Prima di installare il condizionatore d'aria, leggere con attenzione questo manuale d'installazione.
• Questo manuale descrive il metodo d'installazione dell'unità interna.
• Per l'installazione dell'unità esterna, fare riferimento al manuale d'installazione fornito insieme all'unità esterna.
Lea atentamente este Manual de instalación antes de proceder a la instalación del aparato de aire acondicionado.
• Este manual describe el método de instalación de la unidad interior.
• Para la instalación de la unidad exterior, consulte el Manual de instalación que acompaña a la unidad exterior.
Leia atentamente o presente Manual de Instalação antes de instalar o Ar Condicionado.
• O presente manual descreve o método de instalar a unidade interior.
• Para a instalação de uma unidade exterior, siga o Manual de Instalação que acompanha a unidade exterior.
Lees deze installatiehandleiding zorgvuldig door voordat u de airconditioner gaat installeren.
• Deze installatiemethode beschrijft de installatiemethode van de binnenunit.
• Zie voor de installatie van de buitenunit, de installatiehandleiding bij de buitenunit.
Ðáñáêáëþ äéáâÜóôå ðñïóå÷ôéêÜ ôï Åã÷åéñßäéï ÅãêáôÜóôáóçò ðñéí áðü ôçí åãêáôÜóôáóç ôïõ Êëéìáôéóôéêïý.
• Ôï ðáñüí Åã÷åéñßäéï ðåñéãñÜöåé ôç ìÝèïäï åãêáôÜóôáóçò ôçò åóùôåñéêÞò ìïíÜäáò.
• Ãéá ôçí åãêáôÜóôáóç ôçò åîùôåñéêÞò ìïíÜäáò, áêïëïõèÞóôå ôï Åã÷åéñßäéï ÅãêáôÜóôáóçò ðïõ óõíïäåýåé ôçí åîùôåñéêÞ
ìïíÜäá.
(SPLIT TYPE)
(TYPE SPLIT)
(SPLIT-TYP)
(TIPO SPLIT)
(TIPO SPLIT)
(TIPO SPLIT)
(GESPLITST TYPE)
(ÔÕÐÏÓ SPLIT)
MANUEL D’INSTALLATION
INSTALLATIONS-HANDBUCH
MANUALE DI INSTALLAZIONE
MANUAL DE INSTALACIÓN
MANUAL DE INSTALAÇÃO
INSTALLATIEHANDLEIDING
ÅÃ×ÅÉÑÉÄÉÏ ÅÃÊÁÔÁÓÔÁÓÇÓ
Outdoor Unit/Unité extérieure
Außengerät/Unità esterna
Unidad exterior/Unidade exterior
Buitenunit/ÅîùôåñéêÞ mïíÜäá
RAV-SM562AT-E

INSTALLATION MANUAL

Not accessible to the general public
Vente interdite au grand public
Kein öffentlicher Zugang
Non accessibile a clienti generici
No destinado al público en general
Não acessível ao público em geral
Niet geschikt voor huishoudelijk gebruik
Ìç äéáèÝóéìï óôï åõñý êïéíü
SP562AT-E

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-SM562MUT-E

  • Page 1: Installation Manual

    Außengerät/Unità esterna Unidad interior/Unidade interior Unidad exterior/Unidade exterior Binnenunit/ÅóùôåñéêÞ mïíÜäá Buitenunit/ÅîùôåñéêÞ mïíÜäá RAV-SM562MUT-E RAV-SM562AT-E SP562AT-E Please read this Installation Manual carefully before installing the Air Conditioner. • This Manual describes the installation method of the indoor unit. • For installation of the outdoor unit, follow the Installation Manual attached to the outdoor unit.
  • Page 2 ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer. UTILISATION DU NOUVEAU REFRIGERANT Ce climatiseur est d’un type inédit qui utilise le nouveau réfrigérant HFC (R410A) au lieu du réfrigérant traditionnel R22, afin d’éviter la destruction de la couche d’ozone.
  • Page 3: Table Of Contents

    CONTENTS Accessory parts and Parts to be procured locally ... 1 ELECTRICAL WORK ..........15 PRECAUTIONS FOR SAFETY ........2 TEST RUN ..............18 SELECTION OF INSTALLATION PLACE ....4 APPLICABLE CONTROLS ........20 INSTALLATION OF INDOOR UNIT ......6 TROUBLESHOOTING ..........
  • Page 4: Accessory Parts And Parts To Be Procured Locally

    Accessory parts and Parts to be procured locally H Accessory parts Part name Q’ty Shape Usage Installation Manual This manual (Be sure to hand over to customers) Heat insulating pipe For heat insulation of pipe connecting section Installation pattern —— For confirmation of ceiling opening and main unit position Installation gauge For positioning of ceiling position (united with installation pattern)
  • Page 5: Precautions For Safety

    PRECAUTIONS FOR SAFETY • Ensure that all Local, National and International regulations are satisfied. • Read this “PRECAUTIONS FOR SAFETY” carefully before Installation. • The precautions described below include the important items regarding safety. Observe them without fail. • After the installation work, perform a trial operation to check for any problem. Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.
  • Page 6 PRECAUTIONS FOR SAFETY • When the air conditioner is installed in a small room, provide appropriate measures to ensure that in the event of a refrigerant leak the rooms does not exceed the critical level. • Install the air conditioner securely in a location where the base can sustain the weight of the unit adequately.
  • Page 7: Selection Of Installation Place

    SELECTION OF INSTALLATION PLACE WARNING • The air conditioner must be installed in a location that can support the weight of the unit effectively. If the unit is not installed on a foundation that can support its weight effectively, the unit may fall down, resulting in possible human injury.
  • Page 8 SELECTION OF INSTALLATION PLACE REQUIREMENT Selection of installation place • When using the high ceiling (1) or (2) with 4-way In case of continued operation of the indoor unit under discharge system, the draft is apt to be felt due high-humidity conditions as described below, dew may to drop of the discharge temperature.
  • Page 9: Installation Of Indoor Unit

    INSTALLATION OF INDOOR UNIT WARNING The installation of the air conditioning unit must be positioned in a location that can sufficiently support its weight and give protection against adverse environmental conditions. Failure to do so may result in unit damage and possible human injury. Any incomplete installation may also cause possible risk of human injury.
  • Page 10 INSTALLATION OF INDOOR UNIT Dimensional view 595 to 660 Ceiling open dimension 1000 or more Check port 450) Check port 450) Check port 450) Obustacle Drain-up standing-up size Indoor unit 1000 or more Bottom face of ceiling Note) As ABS is used for the drain discharge port of the main unit, the vinyl chlor paste cannot be used.
  • Page 11 Ceiling opening and installation of hanging bolts • Evaluate and determine the piping and wiring requirements inside the ceiling prior to the hanging of the unit. • After installation place of the indoor unit has been determined, create opening in ceiling and install the hanging bolts.
  • Page 12 INSTALLATION OF INDOOR UNIT Installation of indoor unit Hanging bolt M10 flat washer (W3/8 or M10) • Attach the nut (M10 or W3/8: Procured locally) and washer (Ø34 mm) (Accessory) to the hanging bolt. (W3/8 or M10) • Put washers at either side of the T-groove on the hanging bracket of M10 flat washer the indoor unit in order to hang the unit.
  • Page 13: Drain Piping Work

    DRAIN PIPING WORK Pipe material/Insulator and size CAUTION The following materials for piping work and insulation • Install the drain piping so that the water are to be procured locally. drains effectively. Hard vinyl chloride pipe socket for VP25 • Apply heat insulation to prevent dew condensation from forming.
  • Page 14 DRAIN PIPING WORK Connection of drain pipe Check the draining • Connect the hard socket (Procured locally) to the After completion of drain piping, hard socket side of the supplied flexible hose which Check water drains away and that no water leaks from has been installed.
  • Page 15 Thermal insulating process • After checking of the draining, using the supplied thermal insulation fit to the flexible hose leaving no clearance at the connecting port of the indoor unit. • Fit locally procured thermal insulation to the drain pipe leaving no clearance between the supplied insulation. Flexible hose Hose band CAUTION...
  • Page 16: Refrigerant Piping And Evacuating

    REFRIGERANT PIPING AND EVACUATING • Flaring diam. meter size : Refrigerant Piping A (Unit : mm) 1. If the outdoor units are to be mounted on a wall, make sure that the supporting platform is sufficiently strong. The platform should be - 0.4 designed and manufactured to maintain its strength Outer diam.
  • Page 17 Piping with outdoor unit Open the valve fully • Shape of valve differs according to the outdoor unit. Open the valve of the outdoor unit fully. A 4mm- hexagonal wrench is required for opening the valve. For details of installation, refer to the Installation Manual of the outdoor unit.
  • Page 18: Electrical Work

    ELECTRICAL WORK WARNING 1. Using the specified cables, ensure to connect the wires, and fix wires securely so that the external tension to the cables do not affect the connecting part of the terminals. Incomplete connection or fixation may cause a fire, etc. 2.
  • Page 19 Cable connection REQUIREMENT • Be sure to connect the cables matching the terminal numbers. Incorrect connection causes a trouble. • Be sure to pass the cables through the bushing of cabling connection port of the indoor unit. • Keep a margin (Approx. 100mm) on a cable to hang down the electric parts box at servicing, etc. •...
  • Page 20 ELECTRICAL WORK Cabling Remote Controller Cabling 1. Remove a screw and then remove cover of the • Strip off approx. 9mm the cable to be connected. electric parts box. • Non polarity, 2 core cable is used for cabling of the 2.
  • Page 21: Test Run

    TEST RUN Before test run • Before turning on the power supply, carry out the following procedure. 1) Using 500V-megger, check 1MΩ or more exists between the terminal block 1 to 3 and the earth. If 1MΩ or less is detected, do not run the unit. Do not apply to the remote controller circuit. 2) Check the valve of the outdoor unit being opened fully.
  • Page 22 TEST RUN In case of wireless remote controller Procedure Description Remove a small screw which fixes the nameplate of the receiver unit. Remove the nameplate of the sensor section by inserting a minus screwdriver, etc into the notch at the bottom of the plate, and set the Dip switch to [TEST RUN ON].
  • Page 23: Applicable Controls

    APPLICABLE CONTROLS Change of lighting time of filter sign To secure better effect of heating According to the installation condition, the lighting time When it is difficult to obtain satisfactory heating due to of the filter sign (Notification of filter cleaning) can be installation place of the indoor unit or structure of the changed.
  • Page 24: Group Control

    APPLICABLE CONTROLS Group control Simultaneous twin system If combining with an outdoor unit, ON/OFF operation of two indoor units is <Twin system> simultaneously available for the twin system. Outdoor unit Indoor unit Indoor unit • For wiring procedure and wiring method, follow to the Remote controller “Electric work”...
  • Page 25 Procedure example Manual address setup procedure While the operation stops, change the setup. (Be sure to stop the operation of the unit.) CODE No. DATA SETTING TEST UNIT No. R.C. TEMP. ON / OFF TIMER SET MODE TIME SWING/FIX VENT FILTER RESET TEST SET CL...
  • Page 26 APPLICABLE CONTROLS Procedure Description If there is other indoor unit to be changed, repeat Indoor unit No. before setup change is displayed. procedure to change the setup. UNIT CODE No. When the above setup has finished, push DATA SETTING TEST select the indoor unit No.
  • Page 27: Troubleshooting

    TROUBLESHOOTING Confirmation and check When a trouble occurred in the air conditioner, the CODE No. check code and the indoor unit No. appear on the UNIT No. display part of the remote controller. R.C. The check code is only displayed during the operation. If the display disappears, operate the air conditioner according to the following “Confirmation of error Check code...
  • Page 28: Check Code List

    TROUBLESHOOTING Check method On the remote controller (Main remote controller, Central control remote controller) and the interface P.C. board of the outdoor unit, a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P.C. board) operation is provided. Therefore the operation status can be known. Using this self-diagnosis function, a fault and the location of this fault within the air conditioning system can be located, as shown in the table below.
  • Page 29 Check code Wireless remote controller Main Sensor block display Outdoor 7-segment display Check code name Judging device remote of receiving unit controller display Auxiliary code Operation Timer Ready Flash ¤ ¤ — — Indoor TCJ sensor error Indoor ¤ ¤ —...
  • Page 30 Batch alarm of general-purpose equipment control General-purpose equipment — — — interface Differs according to error contents of unit with occurrence of alarm Group control branching unit error TCC-LINK — — (L20 is displayed.) Duplicated central control addresses Terminology TCC-LINK : TOSHIBA Carriea Cominication Link.
  • Page 31 New check code 1. Difference between the new check code and the current system The displaying method of the check code will change from this model onwards. TCC Link Alphabet + Decimal notation, 2 digits Used characters → Display Classification Characteristics of Many classification of communication/ Unused...
  • Page 32 MAINTENANCE Prior to maintenance, ensure the power supply is turned off. WARNING CAUTION Cleaning of the air filter and other parts of the air filter Do not handle the buttons with wet hands as involves dangerous work in high places, so be sure to this will cause the risk of electric shock.
  • Page 33 EH99851801...