Appliance Input Rate (kBTU/hr)
20
Chimney
Minimum Opening** (sq. in.)
Height* (ft)
10
11.3
15
8.6
20
7.5
25
6.6
30
6.2
35
5.7
40
5.3
* Height is from hearth to top of chimney and the minimum height is 10 feet.
** Chart shows minimum opening (sq. in.) for a given height and input rate.
*** Column marked "Max. Input" corresponds to the maximum allowable input rate (kBTU/hr) for the given height.
Although your gas logs are very realistic in appearance, it is not a real burning fireplace and
must not be used for burning solid fuel.
To avoid irreparable damage to the heater or personal injury, matches, paper, garbage, or any
other material must not be placed or thrown on top of the logs or into the flames.
To avoid personal injury, do not touch hot surfaces when the heater is operating. Close
supervision is necessary when the heater is being operated near children.
WARNING:
TAKEN TO NOT DAMAGE THE LOGS.
THE HEATER IS INTENDED FOR USE AS A GAS HEATER MOUNTED IN A VENTED
OR VENT-FREE FIREPLACE AS DESCRIBED IN THESE INSTRUCTIONS. IT SHOULD
NOT BE USED FOR ANY OTHER PURPOSE.
CAUTION:
OF THE HEATER, BE SURE TO READ THE ABOVE SECTION ON "IMPORTANT
SAFEGUARDS".
Your appliance should be cleaned at least once a year to insure proper operation.
All cleaning should be carried out when the heater is cold. Only limited cleaning will be required
under normal use. Dusting the front of the base, the top of the piezo cover, or the control knob
panel may be required occasionally. Do not use any cleaning fluids to clean the logs or any
other part of the heater.
30
40
50
16.6
22.1
28.3
12.6
17.3
21.2
10.8
14.5
18.1
9.6
12.6
15.9
9.1
11.3
14.5
8.0
10.8
13.2
7.5
10.2
12.6

IMPORTANT SAFEGUARDS

IN THE EVENT OF THE LOG BEING REMOVED, CARE SHOULD BE

CLEANING

BEFORE CLEANING OR MOVING LOGS OR OTHER PARTS
60
70
80
35.3
44.2
—–
26.4
32.2
38.5
22.1
26.4
31.2
18.1
22.9
27.3
17.3
20.4
24.6
15.9
18.9
22.1
15.2
18.1
20.4
Page 27
90
100
110
—–
—–
—–
45.4
—–
—–
37.4
43.0
—–
31.2
36.3
43.0
28.3
33.2
37.4
25.5
30.2
34.2
23.8
27.3
31.2
120
MAX
Input*
—–
77.6
—–
98.2
—– 114.2
50.3 121.0
44.2 130.1
39.6 141.2
35.3 158.5