Gas Pressure Check - New Buck Corporation EMBER VISION 100 SERIES Installation Instructions Manual

Vent-free or vented 30”(oak) gas log set vent-free or vented 24”(oak or pine) gas log set for natural or liquid petroleum (l.p.) with optional heat shield model 19hs
Table of Contents

Advertisement

EMBER VISION SERIES/24" PINE LOG SET SHOWN
LEFT SIDE
#8
Check the inlet pressure to the burner to ensure that it is as shown in the table below.
NOTE: The pressure check point is located on right side of valve facing the burner.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa).
MODEL
Gas
Maximum Heat Input
Minimum Heat Input
Gas Inlet Pressure:
Maximum
Minimum
Manifold Pressure
NOTE: On initial installation it may be required to bleed out air in the gas lines. Do this by
holding the control knob and turning the knob to the pilot position for about 30 seconds.
The pressure should be checked with the heater burning and the control set on high.
measuring the pressure, close pressure tap screw, ensuring there are no leaks. Regulator pressure
check screw located above "OFF/ PILOT/ON" knob at right upper corner of valve.
This appliance is equipped for (natural or propane) gas.
#3
#2
#5
#7
FRONT
Figure 2.

GAS PRESSURE CHECK

EMBER VISION 100 AND 200 SERIES
Natural
40,000
31,000
10.5 ins. W.C.
4.5 ins. W.C.
3.5 ins. W.C.
WARNING
Field conversion is not permitted.
Page 10
#1
#4
#6
#9
Propane (LP)
40,000
33,000
13.0 ins. W.C.
10.5 ins. W.C.
10.0 ins. W.C.
RIGHT SIDE