Sony SCD-C222ES Service Manual page 17

Super audio cd player
Hide thumbs Also See for SCD-C222ES:
Table of Contents

Advertisement

TOOLS command (8X): Performs aging, reads adjusting parameters, etc.
No.
Name
Description
81
VERSION
Firmware version is displayed
83
TRAY AGING
Tray open-close aging is performed
Not used for the servicing
84
JITTER
Jitter measurement
85
ERROR RATE
Error rate measurement
CD: C1, C2
SACD: PO, PI1, PI2
86
ALL SRV ON
Apply all servos
Full automatic measurement including PI, FE and TE offset adjustment is
performed
87
DISP ADJ DT
Automatic adjusting parameters are displayed
The offset adjusted values are scroll-displayed in order of RF, VC, FE and
TE
8A
FL TEST
8d
Set Up Init
Set to factory shipping mode
PLAY, REPEAT, DIGIFIL, etc. are initialized
8F
49 TRCK JIT
Used for jitter measurement of 49th music on SACD-S4
QA command (9X)
No.
Name
Description
91
F.JMP CHECK
92
SET CHECK
The set is checked
93
WATER MARK
94
SET AGING
The set aging is performed
Repeat by the specified number of times or until an error occurred
95
DISP ERROR
The content of error recorded to the set is read and displayed
(Error recording) Only one item is recorded
96
D-OUT OnOff
Digital out of CD is turned on or off
98
APDD JITTER
9C
BU DENCHO
The content of error recorded to the set is read, and then the S curve
waveform, traverse waveform, and RF waveform can be checked
successively
9D
P-ON HOUR
Approximate cumulative power supplying time is displayed
(Initialized by 8d command)
9E
RFD OUT
RFD output is turned on or off
SACD jitter measuring mode
How to Apply Servo by Manual Operation
In analyzing failures of the set, the servo may be applied by manual operation. To apply servo in the test mode, use the following method.
1. After setting the test mode, rotate the
2. "61 DISC DETECT" (Disc type check)t"86 ALL SRV ON" (All servos on + auto adjustment)
3. If applying servo while checking the condition one by one, "61 DISC DETECT" (Disc type check)t"31 PI/FE OFSET" (Offset
automatic adjustment)t"14 FSRV ON/OFF" (Focus servo on)t"16 CLV ON/OFF" (CLV servo on)t"44 ADJ TRK DSP " (E-F
balance adjustment)t"15 TSRV ON/OFF" (Tracking servo on)t"17 SSRV ON/OFF" (Sled servo on)t"24 ADJ FCSBIAS" (Fo-
cus bias adjustment)t"27 FOCUS AGC" (Focus auto gain adjustment)t"45 TRACKING AGC" (Tracking auto gain adjustment).
Note: 1. On and off are alternately switched in the same command.
2. For a stop, select "19 ALL SRV OFF" and press the
[
AMS
]
dial to select a command, and press the
l
L
[
AMS
]
l
L
Remarks
Example: Ver 1.00
Number of times and eccentricity
measurement Not used in this set.
Not used for the servicing
Error rate
Not used for the servicing
Use when applying the servo by
manual operation
Refer to STANDARD command (page 15)
Refer to auto check items (page 20)
Refer to auto check items (page 20)
Not used for the servicing
Set when repair completed
Refer to 5-7. SHIPPING MODE (page 25)
For manufacturing line
Not used for the servicing
Remarks
Not used for the servicing
Refer to 5-2. AUTO CHECK (page 20)
Not used for the servicing
Refer to 5-6. AGING MODE (page 25)
Refer to Error Display list (page 26)
Not used in this set.
Not used for the servicing
Refer to 5-8.WAVEFORMS CHECK
(page 27)
In unit of 1 hour
Not used for the servicing
[
l
dial.
SCD-C222ES
AMS
]
dial to enter.
L
17

Hide quick links:

Advertisement

Table of Contents
loading