Adjustment
12
Change temperature probe (only on machines with hot-air nozzle)
.06
● Pull out plug 1.
● Loosen screws 2 and withdraw temperature probe 3.
● Installation in reverse order, observing the requirement.
12 - 9
Requirement
The tip of temperature probe 3 must be positioned in the centre of hot-air tube 4.
Fig. 12 - 07
Wait until the heating element has cooled down! Danger of burns!
Disconnect the mains plug!
Danger from electric voltage!
1
3
4
3
2