Electrolux EDW 1506 Service Manual page 19

Table of Contents

Advertisement

Sequence draining with pressure switch level check
drain pump
Drain Cycle
First draining before every wash cycle 45 sec
Draining after the wash cycles
New draining with sequence draining
-
The draining step contains of 3 time sequences.
In the middle sequence, during time T2 the drain pump is stopped.
-
At the end of the drain step, the water level is checked.
-
If the switch back is reached, the drain step is terminated.
If the switch back isn't reached, the drain step is repeated.
-
A failure code is displayed, if after 2 drain steps, the switch back couldn't be reached.
In this case, the program is stopped.
09.2002 R.K.
1 dr aining sequence
with var iable timing
on
off
T1
T2
(variable)
k.
T1
30 sec
level c heck!
T3
(variable)
(variable)
T2
T3
15 sec
20 sec
20 sec
10 sec
- 19 -
599 515 184 EN