AYAP7FHR
2.2. AE-A9FHR

[4] ELECTRICAL PARTS

1. AY-AP7FHR, AE-A7FHR
DESCRIPTION
Compressor
Indoor fan motor
Outdoor fan motor
Indoor fan motor capacitor
Outdoor fan motor capacitor
Running capacitor
Transformer
Fuse
Reverse valve
Reverse valve coil
2. AY-AP9FHR, AE-A9FHR
DESCRIPTION
Compressor
Indoor fan motor
Outdoor fan motor
Indoor fan motor capacitor
Outdoor fan motor capacitor
Running capacitor
Transformer
Fuse
Reverse valve
Reverse valve coil
BOX
ORANGE
PURPLE
MODEL
REMARKS
5RS084DAA01
220 - 240V, 50Hz, 600W
SFS-230-22-4A
220 - 240V, 50Hz
YDK21-6S-2
220 - 240V,50Hz
400V, 1.5μF
400V, 1.5μF
400V, 20μF
Primary ; AC 220V, 50Hz
Secondary ; AC17.0V, 50Hz
250V, 2.5A
SHF-4H-23U
220 - 240V, 50/60Hz
MODEL
REMARKS
44A233A
220 - 240V, 50Hz, 930W
SFS-230-22-4A
220 - 240V, 50Hz
YDK21-6S-2
220 - 240V,50Hz
400V, 1.5μF
400V, 1.5μF
400V, 40μF
Primary ; AC 220V, 50Hz
Secondary ; AC17.0V, 50Hz
250V, 2.5A
SHF-4H-23U
220 - 240V, 50/60Hz
VALVE
COIL
SITE
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
OUTDOOR
INDOOR
INDOOR
OUTDOOR
OUTDOOR
SITE
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
OUTDOOR
INDOOR
INDOOR
OUTDOOR
OUTDOOR
1 – 5
40μ F 400V
C074