Chapter 1. Product Specification; Specification - Sharp AY-AP7FHR Service Manual

Split system room air conditioner
Hide thumbs Also See for AY-AP7FHR:
Table of Contents

Advertisement

AYAP7FHR
AYAP7FHR
CHAPTER 1.
PRODUCT SPECIFICATION

[1] SPECIFICATION

1. AY-AP7FHR—AE-A7FHR
ITEMS
Cooling capacity
Heat pump
Heating capacity
Moisture removal
Electrical data
Phase
Rated frequency
Rated voltage range
Rated voltage
Cool
Rated current
Heat
Cool
Rated input
Heat
Cool
Power factor
Heat
Compressor
Type
Model
Oil charge
Refrigerant system
Evaporator
Condenser
Control
Refrigerant volume
De-Ice system
Noise level
High
Low
Soft
Fan system
Drive
Air flow quantity
High
Low
Soft
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping
Others
Safety device
Air filters
Net dimensions
Width
Height
Depth
Net weight
NOTE: The conditions of star(
INDOOR UNIT
AY-AP7FHR
kW
2.05
kW
2.4
Liters/h
0.7
Single
Hz
50
V
198 to 264
V
220 - 240
A
3.0 - 2.8
A
3.1 - 2.9
W
635 - 635
W
660 - 660
%
96 - 94
%
97 - 95
Hermetically sealed rotary type
5RS084DAA01
300cc (RB68A or Freolalpha68M)
Louver fin and Grooved tube type
Corrugate fin and Grooved tube type
Capillary tube
670g
Micro computercontroled reverse system
dB(A)
37
dB(A)
33
dB(A)
28
Direct drive
3
7.3
m
/min.
3
6.6
m
/min.
3
3.5
m
/min.
Cross flow fan
Flare type
3/8", 1/4"
O.D φ18
mm
Compressor : Overload protector
Fan motor : Thermal Protector
Fuse, Micro computer control
Polypropylene net (Washable)
mm
810
mm
270
mm
184
kg
9
) marked items sre 'ISO151' : 1994(E), condition T1.
Service Manual
OUTDOOR UNIT
AE-A7FHR
44
28
Propeller fan
730
540
250
28
1 – 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ay-ap9fhrAe-a7fhrAe-a9fhr

Table of Contents