Electrical Parts - Sharp AY-M09AE Service Manual

Multi split system room air conditioners
Hide thumbs Also See for AY-M09AE:
Table of Contents

Advertisement

AY-M09AE
AE-M18AE
For Model AY-M09AE and AE-M18AE
DESCRIPTION
Compressor
Indoor fan motor
Outdoor fan motor
Indoor fan motor capacitor
Outdoor fan motor capacitor
Running capacitor
Transformer
Fuse
Reverse valve coil

ELECTRICAL PARTS

MODEL
2PS192D3AA02
ML-A411
ML-A868
-
-
-
-
-
-
6
REMARKS
220 - 240V, 50Hz, 900W
220 - 240V, 50Hz
220 - 240V, 50Hz
400V, 1µF
440V, 2µF
370V, 25µF
Primary; AC 220V, 50Hz
Secondary; AC14.8V, 50Hz
250V, 3A
220 - 240V, 50/60Hz
SITE
AE
AY
AE
AY
AE
AE
AY
AY, AE
AE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae-m18ae

Table of Contents