Auto Restart - Sharp AY-AP7FHR Service Manual

Split system room air conditioner
Hide thumbs Also See for AY-AP7FHR:
Table of Contents

Advertisement

AYAP7FHR
14. AUTOMATIC FAN SPEED
When the automatic fan speed is selected in cool or heat operation,
the fan speed is automatically changed by the thermostat lines C1 to
C3 in cool operation, and H1 to H4 in heat operation.
b . H E A T o p e r a t i o n
S t a t e s 1 & 7 : " H A M "
S t a t e s 2 & 6 : " H M "
S t a t e s 3 & 5 : " H A L "
S t a t e s 4 : " H U L " , " H L " , O F F
4
3
2
1
P r e s e t t e m p e r a t u r e
H1
H2
H3
H4
5
6
R o o m
7
t e m p e r a t u r e
t r a n s i t i o n
15. OUTPUTS IN EACH OPERATION MODE
Mode
C
Cooling
O
O
Circulating
L
Normal
H
E
Preheat
A
Air Flow
T
Control
ON Defrost
Cooling
D
R
Dehumidiflying
Y
Circulating
16. POWER ON START
If the connecting wire JP4 is cut on the PWB ass'y, when the power is
supplied by turning on a circuit breaker, the air conditioner automati-
cally starts of operation in "AUTO".
(Refer to Figure L-5. ~ L-8. Printed Wiring Board.)

17. AUTO RESTART

Power failure occurs during operation, the unit will restart in the same
operation mode as before after power recovery.
18. PLASMA CLUSTER
Plasma cluster ion mode
SSR2 : ON
3 – 4
Outdoor
Indoor
Valve
Compressor
Fan Motor
Fan Motor
Coil
ON
ON
ON
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON/UL/OFF
ON
ON
UL/OFF
ON
ON
OFF
OFF
OFF
ON
ON
L/UL
OFF
UL/D
OFF
ON
ON
OFF
OFF
D/OFF
OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ay-ap9fhrAe-a7fhrAe-a9fhr

Table of Contents