Xact Digital Control System Error Messages - Titan Skid Basic Owner's Manual

640ix airless sprayer
Table of Contents

Advertisement

Problem
Poor spray pattern.
The unit lacks power.

Xact Digital Control System Error Messages

The following error message screens appear whenever the
Xact Digital Control System detects a problem with the
sprayer. Once a problem occurs and the error message
appears, the sprayer will shut down.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts or electric shock. Always unplug the
sprayer before servicing!
Check Paint Screen (E1)
The Check Paint screen
appears when the pump
pressure drops to a very low
level and the pressure control knob has not been adjusted.
Check the paint level and refill. Restart the sprayer by
following the "Painting" procedure in the Operation section of
this manual.
Check Transducer Screen (E2)
The Check Transducer screen
appears when the transducer
has become disconnected or
is defective. Take the sprayer to a Titan authorized service
center for repair.
Check Motor Screen (E3)
The Check Motor screen
appears when the motor or
motor sensor is defective.
Take the sprayer to a Titan authorized service center for repair.
Low Voltage Screen (E4)
The Low Voltage screen
appears when the sprayer
shuts down because of low
input voltage. Check the power supply and correct the
problem. Restart the sprayer by following the "Painting"
procedure in the Operation section of this manual.
High Motor Temperature Screen (E5)
The High Motor Temperature
screen appears when the
temperature of the motor has
risen too high. Take the sprayer to a Titan authorized service
center for repair.
© Titan Tool Inc. All rights reserved.
Troubleshooting
Cause
1. The spray tip is too large for the
material being used.
2. Incorrect pressure setting.
3. Insufficient fluid delivery.
4. The material being sprayed is too
viscous.
1. The pressure adjustment is too low.
2. Improper voltage supply.
CHECK PAINT
CHECK TRANSDUCER
CHECK MOTOR
LOW VOLTAGE
HIGH MOTOR
TEMPERATURE
Solution
1. Replace the spray tip with a new or smaller
spray tip following the instructions that
came with the spray gun.
2. Rotate the pressure control knob to adjust
the pressure for a proper spray pattern.
3. Clean all screens and filters.
4. Add solvent to the material according to the
manufacturer's recommendations.
1. Rotate the pressure control knob clockwise
to increase the pressure setting.
2. Reconnect the input voltage for 120V AC.
High Control Temperature Screen (E6)
The High Control Temperature
screen appears when the
temperature of the Xact Digital
Control System has risen too high. Take the sprayer to a Titan
authorized service center for repair.
High Load Check Mechanism Screen (E7)
The High Load Check
Mechanism screen appears
when the sprayer shuts down
because of high current or when the sprayer goes into current
fold back mode.. Take the sprayer to a Titan authorized
service center for repair.
Exceeded Pressure Limit Screen (E8)
The Exceeded Pressure Limit
screen appears when the
sprayer pressure exceeds
3300 PSI / 22.8 MPa. Take the sprayer to a Titan authorized
service center for repair.
Communication Error Screen (E9)
The Communication Error
screen appears when the Xact
Digital Control System loses
communication with the control panel. Take the sprayer to a
Titan authorized service center for repair.
15
HIGH CONTROL
TEMPERATURE
HIGH LOAD
CHECK MECHANISM
EXCEEDED
PRESSURE LIMIT
COMMUNICATION
ERROR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents